6.2 Serial Rescue
The “Serial Rescue” procedure loads the entire
firmware and resets the device to factory default
settings (current configuration is overwritten).
It is therefore helpful to note the current setting.
Printing out the “status” page is the quickest way as
the page contains all configuration parameters.
Open your web browser and type in the IP address
of the Barix device in the URL field followed by
“/status” and hit the “Enter” key.
•
Example: “192.168.0.12/status”
To apply the Rescue using a serial cross cable and a
PC running Windows 2000, Windows XP, Linux or a
MAC follow the steps in the “_readme1st.txt”
carefully as there are several different applications
(batch files) to be started depending on the Barix
hardware (new or legacy) and the PCs COM port
number used.
Calculate approximately 2 minutes to complete the
“Serial Rescue” procedure. After a successful rescue
the device is ready for configuration according to
your needs
(see chapter
3 Device Configuration
).
6.3 Web Update
To apply the “Web Update” procedure you will need
a standard web browser and the IP address of the
device (announced by the
SonicIP
feature).
Make sure that the “Web server port” is set to “80”
before starting the procedure.
Calculate approximately 2 minutes to complete the
“Web Update” procedure.