4.
Check if all Portafilters fit properly and
tighten screws firmly.
4.
Remove tamper base by turning from left
to right.
2.
Release lower clamp bolts.
Set up the lower clamp
Once
every
week
Maintenance
3.
Insert the portafilter in-between the
upper- and lower clamp.
Turn the adjustment wheel clockwise to move the
lower clamp up against the Portafilter.
!
!
!
CLEAN
PRESSURE
CLEAN
PRESSURE
CLEAN
PRESSURE
PRESSURE
PRESSURE
PRESSURE
PRESSURE
CLEAN
PRESSURE
WARNING:
Failure to adjust the lower clamp to
optimum working position may
allow contact with moving parts.
Portafilter should not wiggle
!
Improper lower clamp setting may
also cause damage to drive mecha-
nism.
For instruction video check
www.puqpress.com/support
1.
Press “Cleaning”.
2.
Turn the Mythos 90 degrees and get the Allen key.
3.
Unscrew by turning counter-clockwise and remove
the bolt.
5.
Clean cavity with a brush.
1.
Remove the power cable.
5.
Test if the Portafilter fits well.
It should not wiggle.
Use this funtions only
after contact with your
local dealer.
Use this funtions only after contact
with your local dealer.
Cycle counter cannot be reset using
this function.
Tamping cycle time
increases with 0.8 s.
1.
Switch off the power.
Press and Hold the
‘CLEAN’
and
‘+’
button while the power is
switched back on.
“SE”
flashes in the display.
In
standby mode
, press and hold
‘+’
and
‘-’
button for
3 sec.
The display will flash a number for 5 sec.
Multiply this number by 5.000 to get cycle
count.
2.
Press
‘CLEAN’
button to step
through menu
(B to F).
A. Activate menu
NEW TAMP SETTINGS
I. Tamping cycle count
1.
Press the
‘CLEAN’
button to bring tamper in
cleaning position. Now press and hold
‘+’
and
‘-’
button for
3 sec.
Multiply this number by 20 to get cycle count.
II. Cleaning cycle count
B. Not in use
C. Change tamp weight
setting
(KG or LBS)
D. Slow tamp
mode
E. Firmware version
1.
Activate menu and press
‘CLEAN’
1 time so that
‘C0’
is
shown (see step A).
1.
Activate menu and press
‘CLEAN’
2 times so that
‘C1’
is
shown (see step A).
1.
Activate menu and press
‘CLEAN’
3 times so that
‘C2’
is shown (see step A).
1.
Activate menu and press
‘CLEAN’
4 times so that
‘Fr’
is shown (see step A).
2.
Press
‘+’
or
‘-’
to see
the revision number.
2.
Press
‘+’ and ‘-’
for 1 sec. to
reset the device back to default
settings.
F. Reset factory default
2.
Use’+’ and ‘-’ to change setting.
00
= NORMAL TAMPING
01
= SLOW TAMPING
2.
Use
’+’
and
‘-’
to change
setting.
00
= KG
01
= LBS
3.
To finish selection, press
‘CLEAN’
button 4 times to exit
menu.
3.
To finish selection, press
‘CLEAN’
3 times to exit menu.
3.
Press
‘CLEAN’
2 times
to exit menu.
3.
Press
‘CLEAN’
to exit
menu.
2.
‘SE’ not in use. Go to
setting C0 by pressing
‘CLEAN’
button.
Problems
with your
puck falling
out? Use this
setting!