background image

 

3

•  This appliance is intended to be used in 

household and similar applications such as 

staff kitchen areas in shops, offices and other 

working environments; holiday homes, hotels 

and other residential settings; and catering 

and similar non-retail applications. 

•  This appliance can be used by children 

aged from 8 years and above and persons 

with reduced physical, sensory or mental 

capabilities or lack of knowledge and 

experience if they have been given supervision 

or instruction concerning the use of the 

appliance in a safe way and understand the 

hazards involved. Children shall not play with 

the appliance. Cleaning and user maintenance 

shall not be made by children without 

supervision.

•  INTRODUCTION

• 

Premier 46 litre capacity minibar using direct 

compressor cooling technology to give a 

temperature range between 3-10°C. Built-in 

thermostat to control temperature to user’s 

preference. Design features two strong 

removable wire rack shelves, internal LED light 

and built-in security lock. Energy Efficiency 

Class E. Ventilation Space - a minimum space 

of 50mm is required for the rear of the fridge 

and 30mm for the top and both sides. This will 

maximise the efficiency,  performance and 

life of the fridge and also ensure that there 

is sufficient space for the hinge to operate 

effectively.

•  SPECIFICATION

•  Model no: DH12.V2

• 

Temperature range: 3-10°C

• 

Rated current: 0.6A

• 

Voltage: 220-240V

• 

Frequency: 50Hz

• 

Energy efficiency class: E

•  Noise level: 42dB

• 

Volume: 46L

• 

Dimensions (W x D x H): 440 x 470 x 530mm

•  INSTALLATION

•  This unit is designed to be free-standing.

• 

Ventilation Space - a minimum space of 50mm 

is required for the rear of the fridge and 30mm 

for the top and both sides. This will maximise 

the efficiency, performance and the life of the 

fridge and also ensure that there is sufficient 

space for the hinge to operate effectively.

•  Locate the unit away from direct sunlight or 

sources of heat i.e. radiator, stove etc. Extreme 

or cold ambient temperatures may also 

prevent the unit working effectively.

•  DO NOT

 locate the unit in a damp or moist 

location.

• 

Ensure that the floor surface is strong and 

stable enough to support the unit when it is 

fully loaded.

•  Level the unit when in location by using the 

adjustable levelling feet in each corner. 

•  Once in position allow the unit to rest for an 

hour before turning it on. 

• 

Allow the unit 2-3 hours to reach set 

temperature after switching on before placing 

any items in the compartment.

•  The unit is capable of having the door opening 

handed.

•  To change door opening, carefully remove the 

door upper hinge cap using a flat blade.

•  Loosen the three cross head screws, remove 

the hinge and lift off door.

•  Remove lower hinge bracket and replace with  

front foot from the other side.

•  Remove hinge hole plug and place into 

opposite side.

• 

Loosely fix the lower hinge bracket to its new 

position and carefully locate door in place.

• 

Loosely fix upper hinge in place.

•  Check that the door is properly closed, sealed 

and level before tightening all screws.

•  OPERATION 

•  The temperature control dial is accessed at 

the rear of the unit in the lower right corner.

•  To turn the unit on, rotate control knob from 

the O (off) position.

•  Rotate control knob to the required value . 

A setting of ‘5’ will create maximum cooling 

effect  (approx. 3

0

C) and ‘1’ will set working 

internal temperature at approximately 10

0

C.

•  When the set temperature is reached, the 

compressor will stop working.

• 

On first use, set the temperature to maximum 

e.g. ‘5’. and adjust to suit once this is reached.

•  Use the rocker switch close to the control 

knob to turn on the unit’s internal light. 

Summary of Contents for DH12.V2

Page 1: ...Black Model No DH12 V2 Thank you for purchasing a Baridi product from the Dellonda range Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance DH12 V2 Issue 2 18 05 2021 ...

Page 2: ...at the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse see fuse rating in these instructions DO NOT pull or carry the appliance by the power cable DO NOT pull the plug from the socket by the cable DO NOT use worn or damaged cables plugs or connectors Ensure that any faulty item is repaired or replaced immediately by a qualified el...

Page 3: ...maximise the efficiency performance and the life of the fridge and also ensure that there is sufficient space for the hinge to operate effectively Locate the unit away from direct sunlight or sources of heat i e radiator stove etc Extreme or cold ambient temperatures may also prevent the unit working effectively DO NOT locate the unit in a damp or moist location Ensure that the floor surface is st...

Page 4: ... proof of which is required for any claim Symptom Solution Unit does not operate Not plugged in Fuse circuit breaker failure Turns on and off frequently Poor cooling Room temperature higher than normal Door opened too often Door not properly closed Temperature control incorrectly set Door gasket not sealing Not enough space around unit Vibrations Check to assure unit is level Noisy unit Contractio...