HFXE LED 

Combined LED DRIVER and EMERGENCY INVERTER 

 for Ex-ENVIRONMENT 

 

Barel AS  

Revision 1 

Date 23.04.2021 

www.barel.no/

 

CONTENT 

1

 

General ................................................................................................................................................. 2

 

1.1 

Manufacturer ......................................................................................................................................... 2 

1.2 

Applications ........................................................................................................................................... 2 

2

 

Approvals .............................................................................................................................................. 2

 

3

 

Technical data ....................................................................................................................................... 3

 

3.1 

Product range ........................................................................................................................................ 3 

3.2 

Mechanical data .................................................................................................................................... 3 

3.3 

Expected lifetime ................................................................................................................................... 4 

4

 

Installation ............................................................................................................................................ 4

 

4.1 

Schedule of limitations .......................................................................................................................... 4 

4.2 

Electrical connection ............................................................................................................................. 5 

4.3 

Battery ................................................................................................................................................... 5 

4.4 

Operation ............................................................................................................................................... 5 

4.5 

Cable ...................................................................................................................................................... 6 

5

 

What to do if... ...................................................................................................................................... 7

 

 

Summary of Contents for HFXE LED

Page 1: ...ENVIRONMENT Barel AS Revision 1 Date 23 04 2021 www barel no CONTENT 1 General 2 1 1 Manufacturer 2 1 2 Applications 2 2 Approvals 2 3 Technical data 3 3 1 Product range 3 3 2 Mechanical data 3 3 3 E...

Page 2: ...7 Explosive atmospheres Part 0 Equipment General requirements IEC 60079 7 2015 AMD1 2017 Explosive atmospheres Part 7 Equipment protection by increased safety e IEC 60079 18 2014 AMD1 2017 Explosive a...

Page 3: ...t 90min 10 Emergency output 180min 10 ARC 600 0 16 0 06A 0 84 28 35mA 28mA ARC 1200 0 29 0 12A 0 94 17 28mA 24mA ARC 600 0 26 0 12A 0 92 22 60mA 44mA ARC 1200 0 57 0 22A 0 98 10 47mA 25mA ARC 600 110m...

Page 4: ...pply before LED modules are disconnected Connect all components battery and LED module Check that all connections are made to the correct port tightened to the correct torque and that no wires are loo...

Page 5: ...e aluminium chassis is internally connected to the gnd pin DC input Connect to N and to L L1 L4 Connect L1 via switch to allow battery charging while light is switched off Indicator LED to be connecte...

Page 6: ...d battery at the same time will reset the test timer Test program is conducted acc to IEC 62034 Indicator LED green no self test Indicator LED red green self test System status Action Continuous green...

Page 7: ...uming operation after a fault is detected Contact Barel if no fault was found and the reset does not restart the unit Do not attempt to open or repair these units Both HFXE and ARC should be replaced...