RESPECT FOR ELECTRICITY
You are only allowed to install equipment on
loose leads, such as multi-way extension
leads, plugs, extension leads, bulb-holders
and to change existing wall sockets and
switches if you have the necessary skill and
knowledge to do this kind of work. Incorrect
installation can cause danger to life and a
fire risk.
New installation and extensions to existing
electrical wiring must only be done by a
competent electrician.
Sensor coverage angle
Sensor more sensitive
Sensor less sensitive
Walking test
The purpose of the walking test is to check and adjust the sensing area of the movement detector.
Run the “LUX” knob towards the sunshine, the “SENSE” knob towards “-” and the “TIME” knob
towards “-”.
Start walking outside the sensing area of the movement detector and walk slowly through the area
until the movement detector is activated.
Settings
The LUX knob:
Turning the LUX knob anti-clockwise adjusts light sensitivity from dark to light.
The TIME knob:
By turning the TIME knob clockwise, you adjust the time that you want the movement detector to be
activated once it has started.
The SENSE knob:
By turning the SENSE knob clockwise, you increase the sensing area of the movement detector.
NOTE!
Do not remove the lens cover, since the sensor could be damaged.
Specification:
Type:
JQ-26
Rated voltage:
220-240V~50Hz
Load capacity:
Max. 1200W
Monitoring area:
> 8m (at temp < 25°C), 180º
Time range:
from 10 ±5 sec to 10 ±3 min
Lux range:
from < 10LUX to daylight
Encapsulation class: IP44
180°