background image

Version 1.02

  |  

T3-OPPAD

 TFT Remote Keypad IP55 User Guide   |   

3

www.

bardac

.com

Allowed System Configurations

Different drive models can be used on the same 

T3-OPPAD

 network provided a unique communications address is assigned to 

each.

 

NOTE

 Cannot be used with Master – Slave or Cascade Control

Keypad and Display Layout

The illustration below explains the main features of the 

T3-OPPAD

.  Please note that some features and display messages are specific 

to certain variants of the 

drive

 family.

TFT Display

Product Name 

Shows the drive type that the 

T3-OPPAD

 is 

connected to.

Main Displayed Parameter 

Shows which of the selectable parameters  

is currently being shown on the main display, 

e.g. Motor Speed, Motor Current etc.

Operating Information 

Provides a real time display of key operating 

information, e.g. output current and power.

Quick Help Button 

Provides access to short description 

of the displayed messages.

Function Button 1 

See specific drive user guide for 

actual function.

Start Button 

When in keypad mode (or HAND 

for Eco), used to start the drive.

Stop / Reset Button 

Used to reset a tripped drive.
When in keypad mode (or HAND for Eco), 
used to stop the drive.

Name

01

Drive Address 

Drive serial communication address.

Navigate Button 

Used to display real-time information, 

to access and exit parameter edit mode 

and to store parameter changes.

Function Button 2  

See specific drive user guide for actual 

function.

Up Button 

Used to increase speed in keypad 

mode or increase parameter values in 

parameter edit mode.

Down Button 

Used to decrease speed in keypad 

mode or decrease parameter values in 

parameter edit mode.

STOP

15kW

400V

3Ph

Summary of Contents for T3-OPPAD

Page 1: ...Installation Operating Instructions User Guide T3 OPPAD TFT Remote Keypad IP55...

Page 2: ...standard 2 wire 5V differential Operational 10 50 C Storage 40 C 60 C 95 non condensing IP55 25m 82 5ft shielded twisted pair Mechanical Installation Dimensions 1 10mm 100mm 90mm 80mm Through Panel M...

Page 3: ...Operating Information Provides a real time display of key operating information e g output current and power Quick Help Button Provides access to short description of the displayed messages Function B...

Page 4: ...PPAD is used on networks with multiple drives the user can change the drive address to set up communication with another drive in the same drive network at anytime Select Drive Address xx Select Drive...

Page 5: ...9kW 23 7Hz 23 7Hz 15 3A 23 7Hz 15 3A Drive Inhibited The STO connections are not made Drive Stopped Disabled Drive is enabled running display shows the output frequency Hz Press the Navigate key to se...

Page 6: ...equired parameter Display will show the present parameter value on the lower line of the display Press the Navigate key for 1 second Adjust the value using the Up and Down keys Display will show the m...

Page 7: ...ting the T3 OPPAD ID 1 or 2 so that two T3 OPPADs can be connected to a single drive or network of multiple drives Troubleshooting Symptom Explanation Select drive address xx displayed after SCAN mess...

Page 8: ...82 OPTFT IN_V2 00 82 OPTFT IN_V2 00 Bardac Drives 40 Log Canoe Circle Stevensville MD 21666 410 604 3400 888 667 7333 bardac com driveweb com automationthings com...

Reviews: