Version 1.02
|
T3-OPPAD
TFT Remote Keypad IP55 User Guide |
3
www.
bardac
.com
Allowed System Configurations
Different drive models can be used on the same
T3-OPPAD
network provided a unique communications address is assigned to
each.
NOTE
Cannot be used with Master – Slave or Cascade Control
Keypad and Display Layout
The illustration below explains the main features of the
T3-OPPAD
. Please note that some features and display messages are specific
to certain variants of the
drive
family.
TFT Display
Product Name
Shows the drive type that the
T3-OPPAD
is
connected to.
Main Displayed Parameter
Shows which of the selectable parameters
is currently being shown on the main display,
e.g. Motor Speed, Motor Current etc.
Operating Information
Provides a real time display of key operating
information, e.g. output current and power.
Quick Help Button
Provides access to short description
of the displayed messages.
Function Button 1
See specific drive user guide for
actual function.
Start Button
When in keypad mode (or HAND
for Eco), used to start the drive.
Stop / Reset Button
Used to reset a tripped drive.
When in keypad mode (or HAND for Eco),
used to stop the drive.
Name
01
Drive Address
Drive serial communication address.
Navigate Button
Used to display real-time information,
to access and exit parameter edit mode
and to store parameter changes.
Function Button 2
See specific drive user guide for actual
function.
Up Button
Used to increase speed in keypad
mode or increase parameter values in
parameter edit mode.
Down Button
Used to decrease speed in keypad
mode or decrease parameter values in
parameter edit mode.
STOP
15kW
400V
3Ph