Manual 2100-535
Page
58 of 71
W24G1DB 230/208-60-3
LP
C
CC
HP
C
Y
AL
R
C
LP
C
M
INUT
E
S
4
2
3
5
R
1
GROUND TERMINAL
15
PINK
L1
BLUE
BLUE
1
2
3
4
5
6
8
9
7
12
10 11
BL
U
E
BL
U
E
L2
BL
U
E
A
L3
A
BL
U
E
PURPLE
PURPLE
NO
C
MV
MV
32
ORA
NGE
YELLOW
YELLOW/BLACK
YELLOW
YELLOW
Y
E
LLO
W
YELLOW
YELLOW/BLACK
YELLOW/RED
Y
E
LLO
W
YELLOW
Y
E
LLO
W
YELLOW
Brown
Brown
RED
RE
D
RE
D
RED/WHITE
63
RED
Thermostat
Black
64
Black
RE
D/
W
HI
T
E
for Bard use only.
32
Wire Identification numbers
Freeze
99
RED
RED/WHITE
32
RED
BLACK
RED
R
C
240V
DRAFT BLOWER
2
PL
1
1
208V
COM
BR
RE
D
Indoor
INDUCED
Fan Motor
Indoor Fan
Capacitor
Evaporator Section
COMPRESSOR
RE
D
L1 L2
T1 T2
32
L3
CONTACTOR
40
TRANSFORMER
T3
PHASE MONITOR
40
OPERATION
208V TAP FOR 208V
MOVE RED WIRE TO
25
RED
28
RED
29
30
31
41
42
43
RE
D
38
39
32
27
38
RE
D
39
BL
AC
K/
W
H
ITE
37
PURPLE/WHITE
66
ORANGE
RE
D/
W
HI
T
E
68
BLACK/WHITE
63
62
66
Y
E
LLO
W
66
PURPLE/WHITE
WHITE
ORANGE
65
BLACK
BLACK/
Y
E
LLO
W
32
PINK
B
ROW
N
BLACK
65
PINK
CONTROL
67
DEHUM
YELLOW
61
RELAY
LOCKOUT
BL
AC
K
BL
AC
K
69
BLACK
BLACK
BL
AC
K
SPEED
150
BL
AC
K/
W
H
ITE
BL
AC
K/
W
H
ITE
135
BLACK/WHITE
BLACK
BL
AC
K
120
FUSE
BL
AC
K
BLACK
P3
BROWN
GRAY
B
ROW
N
BL
AC
K/
W
H
ITE
BLACK
(OPT.)
208/230-60-3
BL
AC
K
USE COPPER CONDUCTORS
SUITABLE FOR AT LEAST 75° C
TERM. BLOCK
BL
AC
K/
W
H
ITE
35
35
35
VALVE
VALVE
GAS
THREE WAY
32
27
37
35
32
32
32
32
LIMIT
FLAME
LIMIT
PRIMARY
59
ROLLOUT
SPARK IGNITOR
32
FLAME SENSOR
SECONDARY
SWITCH
T3
T1
T2
Bard Mfg. Co.
Bryan, Ohio
4085-249
Low Voltage
High Voltage
Optional
PRESSURE
Field
36
Factory
32
CONTROL (OPT.)
LOW AMBIENT
44
A
34
33
20
18
32
32
32
BLOWER SPEED COLOR CODE
HIGH
BLACK
MEDIUM
BLUE
LOW
RED
SWITCH
MODULE
CONTROL
LOW
Compressor
HIGH
PRESSURE
21
SWITCH
23
PRESSURE
COMPRESSOR
MOTOR
INTEGRATED FURNACE CONTROL
FAN
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A
OUTDOOR
WHICH IS 250°C HIGH VOLTAGE CABLE
TEMPERATURE RATING OF AT LEAST 105° C EXCEPT THE IGNITION CABLE
13
LOW VOLTAGE STRIP
BREAKER
CIRCUIT
11
CAPACITOR
IF ANY ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
16
WIRES CONNECT
IF OPTION
NOT USED
Model C. Breaker Fan Capacitor
W24G1DB
25A
5/370
Summary of Contents for W24G1DA
Page 13: ...Manual 2100 535 Page 13 of 71 FIGURE 2A MOUNTING INSTRUCTIONS FOR W42G W48G AND W60G...
Page 16: ...Manual 2100 535 Page 16 of 71 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS...
Page 26: ...Manual 2100 535 Page 26 of 71 FIGURE 12 GAS PIPE CONNECTION W24G W36G W42G W60G...
Page 57: ...Manual 2100 535 Page 57 of 71 W24G1DA W48G1DA W60G1DA 230 208 60 1...
Page 59: ...Manual 2100 535 Page 59 of 71 W24G1DB W48G1DB W60G1DB 230 208 60 3...
Page 61: ...Manual 2100 535 Page 61 of 71 W24G1DC 460 60 3...
Page 63: ...Manual 2100 535 Page 63 of 71 W30G1DA W36G1DA W42G1DA 230 208 60 1...
Page 65: ...Manual 2100 535 Page 65 of 71 W30G1DB W36G1DB W42G1DB 230 208 60 3...
Page 67: ...Manual 2100 535 Page 67 of 71 W30G1DC W36G1DC W42G1DC 460 60 3...
Page 71: ...Manual 2100 535 Page 71 of 71 W48G1DC W60G1DC 460 60 3...