Site~Rite Vision* Ultrasound System 

Technical Manual

          9770057

Summary of Contents for Ultrasound System

Page 1: ...Site Rite Vision Ultrasound System Technical Manual 9770057...

Page 2: ...ons for use Drip Proof Equipment Federal U S A law restricts this device to sale by or on the order of a physician Medical Electrical Equipment Classified by CSA with respect to Electric Shock Fire an...

Page 3: ...n Display Tilt Locking the Casters General Specifications Operating and Storage Conditions A C Adapter Specifications System Battery Specifications EMC Tables Leakage Current 2 1 2 1 1 2 1 2 2 1 3 2 2...

Page 4: ...nnection on the side of the unit Press and hold the power button on the display for three seconds to turn the system on or off The power LED indicates that the system is on Note In standby mode the sy...

Page 5: ...er cable is identical on both ends Both ends are compatible with both the printer and Site Rite Vision Ultrasound System Note The AC adapter cable must be inserted with the flat side of the connector...

Page 6: ...onnect the probe to the display Step 1 Insert Probe Connector Step 2 Twist to Lock Lock Battery Not in use In use Charging Charging Powered A C Adapter Detached Detached Attached Attached System Power...

Page 7: ...Display and Computing Platform Location Exterior Within sheet metal housing Within plastic housing Within sheet metal housing Within sheet metal housing Within sheet metal housing Within sheet metal h...

Page 8: ...3 3V Power Supply Power Connections are shown in blue Data Control Connections are shown in black 5V Power Supply 3 3V Power Supply Microcontroller AC Adapter 24V 6 25A Output AC Power Microcontroller...

Page 9: ...attery and microcontroller The battery charges when wall A C is connected Power for the computing and display platform for function and internal battery charging Power for the microcontroller Microcon...

Page 10: ...VDC Input Frequency VAC 24 5 5 5 47 63 9 3 5 Power Specifications Voltage Inputs Voltage Outputs A C Adapter Power Supply Specifications Fusing The Site Rite Vision Ultrasound System has several fuses...

Page 11: ...ol point of the Site Rite Vision Ultrasound System It launches and closes applications and offers configuration options The operating instructions for each application are described in their respectiv...

Page 12: ...oard arm with a inch socket wrench After the arm has been positioned the fasteners can be tightened to lock the arm in position Note Tightening the keyboard arm fasteners too much will prevent the use...

Page 13: ...tand handle is designed to fold down for storage and fold up for transport The hinge will function after the handle has been lifted up To fold handle down The handle can be put in the transport positi...

Page 14: ...position Note Extending the rotation of the display more than 80 in either direction could result in the system tipping causing injury and or damage to the system The display can be tilted by rotatin...

Page 15: ...wo are dark gray in color one is light gray in color The dark gray caster locks fix the position of the casters but still allow the casters to roll The light gray caster lock is a brake and fixes the...

Page 16: ...dity Input Voltage Charge Time Full Power Sources Monitor Size Storage Humidity Input Current Max Power Consumption IEC 60601 1 59 F to 104 F 10 C to 40 C XP Power Lithium Ion 14 W x 12 H x 5 D 24 VDC...

Page 17: ...trasound System or shielding the location Technical Specifications RF Emissions CISPR 11 RF Emissions CISPR 11 Harmonics IEC 61000 3 2 Flicker IEC 61000 3 3 Group 1 Class A Class A Complies The Site R...

Page 18: ...of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospita...

Page 19: ...ansmitter Separation m 150 kHz to 80 MHz D 1 2 P 1166 3689 1 1666 3 6893 11 6666 Immunity Test Compliance Level EN IEC 60601 Test Level Electromagnetic Environment Guidance The Site Rite Vision Ultras...

Page 20: ...ncluding single faults Supply Voltage Supply Frequency Measured Max Remarks EN N C 264Vrms 63Hz 18 A B 25 A A EN S F C 264Vrms 63Hz 29 A B 40 A A P N C 264Vrms 63Hz 5 A B 7 A A Ultrasound probe P S F...

Page 21: ...ower button for at least 3 seconds to power on Connect system to an A C outlet for operation and battery recharge Note If error persists contact the Bard Access Systems technical clinical support at 8...

Page 22: ...ort at 800 443 3385 Printer error Forgot System Password Printer problems Continued from previous page Error Solutions Files fail to transfer Message Error Trasferring File or Status Processing Failur...

Page 23: ...Systems technical clinical support at 800 443 3385 Follow the recommended image optimization in Table 5 4 and 5 5 See the Site Rite Vision Ultrasound System Instructions for Use for additional informa...

Page 24: ...ld be used for deep imaging Gain adjusts overall image brightness TGC adjusts brightness in sections of the image Adjust Contrast to user preference and procedural need Adjust power Save as user prese...

Page 25: ...cture Black indicates flow information is outside the flow range Adjust Gain Adjust power Save as user preset Increasing gain will enhance the Doppler data but may add noise red blue speckles in non t...

Page 26: ...ble Revision date September 2010 Site Rite Vision Ultrasound System Manufactured for Bard Access Systems Inc 605 North 5600 West Salt Lake City UT 84116 U S A 1 801 522 5000 Customer Service 1 800 545...