background image

Manual 2100-319F
Page

2 of 10

CONTENTS

Getting Other Information and Publications

3

QT

EC

 Wall Sleeve General Information

Shipping Damage .................................................. 4
General .................................................................. 4

Installation Instructions

Installation Wood Framed Walls ...................... 4 & 6
Installation Masonry Construction Walls .......... 6 & 7
Accessory Item – QCDS48
Installation with 16" Thick Walls ............................ 8
Installation with 19" Thick Walls ............................ 8
Installation with 23" Thick Walls ............................ 8
Installation with 30" Thick Walls ............................ 8
Accessory Item - QCDS48
Condensate Disposal System ................................ 9
Attachment of Wall Sleeve to Unit ....................... 10

Figures

Figure 1

Wood Framed Installation ..................... 4

Figure 2

Application of Sealant to 2 x 6 Plate ..... 5

Figure 3

Application of Sealant to Flanges ......... 5

Figure 4

Masonry Construction Installation ......... 6

Figure 5

Typical Installation With 14"
Maximum Wall Thickness ..................... 7

Figure 6

Condenser Fill Plate Application ........... 8

Figure 7

QCDS48 Condensate Disposal
System .................................................. 9

Figure 8

Attaching Base Assembly to Sleeve
Showing Caulking ............................... 10

Summary of Contents for QTEC QWS48A

Page 1: ...l No 2100 319F Supersedes 2110 319E File Vol II Tab 14 Date 11 07 05 Bard Manufacturing Company Bryan Ohio 43506 Since 1914 Moving ahead just as planned QTEC Wall Sleeve Models QWS48A QWS48A 16 QWS48A...

Page 2: ...llation with 23 Thick Walls 8 Installation with 30 Thick Walls 8 Accessory Item QCDS48 Condensate Disposal System 9 Attachment of Wall Sleeve to Unit 10 Figures Figure 1 Wood Framed Installation 4 Fig...

Page 3: ...g Systems QTEC Installation Instruction Manual Bard 2100 288 FOR MORE INFORMATION CONTACT THESE PUBLISHERS ACCA Air Conditioning Contractors of America 1712 New Hampshire Avenue NW Washington DC 20009...

Page 4: ...er studs to support the header and to provide a structural member on which to fasten the sleeve See Figure 1 All of the dimensions are referenced from the finished floor height After the opening is fr...

Page 5: ...SEALANT TO FLANGES FIGURE 2 APPLICATION OF SEALANT TO 2 X 6 PLATE FRONT VIEW SLEEVE OPENING TREATED 2 X 6 BOTTOM SUPPORTAND SEAL PLATE APPLY CONSTRUCTION ADHESIVE TO SEAL APPLY CONSTRUCTIONADHESIVE TO...

Page 6: ...ll Information for the drain installation is contained in the QTEC Installation Instructions FIGURE 4 MASONRYCONSTRUCTIONINSTALLATION INSTALLATION MASONRY CONSTRUCTION WALLS For masonry construction w...

Page 7: ...stallation is contained in the QTEC Installation Instructions square in the opening A slope is built into the bottom of the sleeve from the inside to the outside This will allow any water that gets in...

Page 8: ...plate and secure with the three screws INSTALLATION WITH 23 THICK WALLS When an application is required on a building with 23 wall a Wall Sleeve model number QWS48A 23 is required The installation of...

Page 9: ...attaches to the side of the sleeve The drain box has a rear drain and an overflow The rear drain assembly installs in the rear drain of the QTEC This system allows the QTEC unit to be installed or rem...

Page 10: ...re there is not adequate clearance to drive the screws into the cabinet sides The attachment can be made from inside the unit There are two threaded studs extending from the room side of the sleeve to...

Reviews: