3. Installation procedures
Lamp 4
Lamp 3
Lamp 2
Lamp 1
Image 3-2
4. Pull the cables through the gap in the optical base.
3.2
Mounting the new cables
Necessary parts
Wire ties
How to mount
1. Unpack the cables and mark both sides as described in the next table.
Cable number
Indication on cable
Z34720315
/ or 1
Z34720325
// or 2
Z34720335
/// or 3
Z34720345
//// or 4
2. At the bottom side, plug one side of the cables in the correct position.
Cable with mark :
Into lamp :
Connector number
/ or 1
lamp 1
J501
// or 2
lamp 2
J502
/// or 3
lamp 3
J503
//// or 4
lamp 4
J504
8
R59770193 LAMP INFO CABLES CLM 22/05/2008