1.3
Environmental condition check
1.3.1
Environmental condition check
A Barco Media Server must always be mounted in a manner which ensures both air
inlets and outlets are free. For installations in environments where the device is subject
to excessive dust, then it is highly advisable and desirable to have this dust removed
prior to it reaching the device clean air supply. Devices or structures to extract or shield
excessive dust well away from the device are a prerequisite; if this is not a feasible
solution then measures to relocate the device to a clean air environment should be
considered.
It is the customer’s responsibility to ensure at all times that the device is protected from
the harmful effects of hostile airborne particles in the environment of the device. The
manufacturer reserves the right to refuse repair if a device has been subject to negligence,
abandon or improper use.
1.3.2
Environmental conditions
Table summarizes the physical environment in which the Barco Media Server may be
safely operated or stored.
Non-Operating
Operating
Environment
–10°C (14°F) to 60°C (140°F)
0°C (32°F) to 40°C (104°F)
Ambient temperature (t
a
)
n.a.
Clean office environment
(equivalent with clean room
standard ISO 14644-1 ISO
Class 9)
Air cleanliness
0% to 95% RH Non-Con-
densed
5% to 85% RH Non-con-
densed
Humidity
–60 m (–197 ft) to 10000 m
(32810 ft)
–60 m (–197 ft) to 3000 m
(9843 ft)
Altitude
Table 1.2. Environmental conditions
1.3.3
Environment
Do not install a Barco Media Server in a site near heat sources such as radiators or air
ducts, or in a place subject to direct sunlight, excessive dust, or humidity. Be aware that
room heat rises to the ceiling; check that temperature near the installation site is not
excessive.
15
Barco Pn: 60600319
Barco Media Server XHD-Series Safety Guide
Section 1: Safety