R5914435. /00
UST-Lens for G100 series
14
Note:
Make sure the safety cable is tightened around the lens before tightening the U-bolt nuts.
7.
Place the shackle through the free loop end of the safety cable.
8.
Mount the lens in the projector.
9.
Secure the safety cable around the truss and secure the shackle by turning the safety ring of the shackle
over the open end.
2.4 Mounting the UST lens
Required tools
•
Allen wrench 5 mm
•
Allen wrench 3 mm
Required parts
•
Base plate
•
Lens holder module
•
Lens clamp module
•
Hex screws M6 (x3)
How to mount?
1.
Turn the projector on its top cover.
2.
If the projector is to be mounted in the UDX frame, make sure to
first
mount the frame adapter plate.
Note:
For more information on how to mount the adapter plate and mounting the projector in the
rigging frame, see the projector installation manual.
3.
Place the bottom support plate on the bottom plate of the projector as illustrated. Make sure that the
fixation holes match the holes in the bottom plate.
Image 2
–
10 Mount bottom plate on the front side of the projector
Tip:
The blue circle is the ideal screw location
4.
Drive in the three M6 screws. Use a 5 mm Allen wrench.
5.
Turn the projector back on its feet.
Note:
If the projector is to be mounted in the rigging frame, do this first. For more information,
see the installation manual of the G100.
6.
Carefully insert the lens into the lens holder.