2. Safety Information
PR
RESTRICTED
AREA
RESTRICTED
AREA
Image 2-2
USA market
For LIPs (Laser Illuminated Projectors) installed in the USA market other restriction zone conditions apply.
Lip’s for installation in restrained environment (cinema theaters) shall be installed at height vertically above the
fl
oor such that the
bottom plane of the hazard distance zone shall be no lower than 2.5 meters above the
fl
oor. Horizontal clearance to the hazard
distance zone shall be not less than 1 meter.
Lip’s for installations in unrestrained environment (large venues,..) shall be installed at a height vertically above the
fl
oor such that
the bottom plane of the Hazard distance Zone shall be no lower than 3 meters above the
fl
oor. Horizontal clearance to the hazard
distance zone shall be not less than 2.5 meters. Any human access horizontally to the Hazard Zone, if applicable, shall be restricted
by barriers. If human access is possible in an unsupervised environment, the horizontal or vertical clearances shall be increased to
prevent exposure to the hazard distance zone.
In addition for temporary installations (e.g.: rental and staging, lease, events …) the following requirements apply:
•
This product can only be installed by Barco or sold or leased only to valid laser light show variance holders. In other words
our installers are required to have an approved laser light show variance. Such installers may currently hold a valid variance
for production of Class IIIb and IV laser light shows and/or for incorporation of the RG3 LIPs into their shows. Dealers and
distributors are also required to obtain a valid laser light show variance.
•
This product shall be located in such a way that all propagating beam paths within the Restriction Zone, and the audience can
be directly observed at all times.
•
Effects other than front or rear screen projections shall not be performed.
•
Communication shall be maintained with other personnel assisting in surveillance of the LIP projection.
•
In the event of any unsafe condition, immediately terminates (or designate the termination) of LIP projection light.
Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at the projector side
is considered as a reliable disconnect device. When required to switch off the projector, disconnect the power cord at the projector
side. In case the power input at the projector side is not accessible (e.g. truss mount), the socket outlet supplying the projector shall
be installed nearby the projector and be easily accessible, or a readily accessible general disconnect device shall be incorporated
in the
fi
xed wiring.
Laser light shows can be requested via the FDA online eSubmitter portal or via FDA Form FDA Form 3147 referencing to Barco’s
variance approval 2016-V-0144.
2.6
HD for fully enclosed projection systems
HD
Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface
unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to
be) unsafe for exposure if the distance from a person to the light source is less than the HD.
12
R5906787 THOR 26/01/2018
Summary of Contents for Thor
Page 1: ...Thor User manual R5906787 02 26 01 2018...
Page 6: ...Table of contents 2 R5906787 THOR 26 01 2018...
Page 8: ...1 Welcome 4 R5906787 THOR 26 01 2018...
Page 26: ...3 Lenses Lens selection 22 R5906787 THOR 26 01 2018...
Page 34: ...4 Input Communication 30 R5906787 THOR 26 01 2018...
Page 62: ...6 Starting up 58 R5906787 THOR 26 01 2018...