R5906788-03
Thor series
30
The hoses for the RED, GREEN and BLUE laser cluster cooling have a larger diameter size than the hoses for
the DMD cooling. However, take into account that the couplings are of the same type and size. So, ensure to
connect the right hose with the right cooling channel.
See Barco website for available kits of hoses and corresponding ordering information.
Image 3-7: Hose with 90° angle female coupling.
Image 3-8: Hose with 90° angle male coupling.
For chillers and hoses ordering information see Barco website.
3.3 Safety system
Safety controller
The projector is equipped with a safety controller which is located inside the mains compartment. This safety
controller operates independent from the projector electronics and has its own power supply. The safety
controller is connected with the beam stop button (reference 1 Image 3-9) and the beam enable key
(reference 2 Image 3-9) of the projector. In case the beam stop button is pushed or the beam enable key is
switched off the safety controller immediately triggers the relay to disconnect the power from all Power Supply
Units (PSU) of the lasers.
Beam enable key
The beam enable key (reference 2 Image 3-9) must be in the
“
on
”
position to be able to activate the lasers. In
case the safety controller is triggered by an interlock event (internal or external) then, after restoring the
interlock, the beam enable key must be switched off and on to reset the safety controller. Otherwise, the lasers
can not be activated.
External beam enable key
The beam enable key is built-in but there is also a connection available for an additional, external switch which
is connected in series with the internal beam enable key. This means that both keys must be switched on to
power the PSUs of the lasers.
Beam stop button
The beam stop button (reference 1 Image 3-9) is easy accessible by the operator. Pushing the beam stop
button will result in disconnecting the power from all Power Supply Units (PSU) of the lasers. The beam stop
button requires a quarter turn to restore its normal operating position. After restoring the beam stop button the
beam enable key must be switched off and on to reset the safety controller.
External safety interlocks
Two external safety interlocks can be connected with the safety controller (e. g. to connect an infrared field
scanning device for the restricted HD area). In case an external safety interlock switch opens the safety
controller immediately opens relays to disconnect the power from all Power Supply Units (PSU) of the lasers.
The safety controller requires per interlock a double pole switch. It is not sufficient to break only one of the two
interconnections. Both contacts should be opened and closed simultaneously. If only one contact is opened
without the second one, the projector will not start up again after the contact is closed. To recover from such
an error, open and close the external interlock with both contacts simultaneously, then turn the beam enable
key off and on.
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...