2. Installation requirements
2.1
Mechanical requirements
Support structure
The support structure has to be provided and installed by the customer because they vary from system to system. Although, the
following must be taken into account and must be precisely calculated on individual basis:
1.
Weight tolerances
: Ensure that the support structure and the
fl
oor on which or the wall against which the support structure
has to be installed, is able to handle the complete weight of the
fi
xed TF-10 LED display.
2.
Environmental conditions
: Humidity, wind, temperatures, rain, etc.
3.
Location
: Outdoor, altitude, etc.
4.
Ground stability
5.
Front clearances
: For optimal impact ensure that there is suf
fi
cient free area in front of the TF-10 display and respect the
maximum viewing distance.
6.
Local regulations regarding such installations
W
ARNING
:
Never construct a TF-10 display if there is uncertainty regarding the stability of an installation or
the load holding capabilities. If there are doubts on a systems viability, consult Barco for advice on profes-
sional rigging organizations.
Individual basis
Support structures must be assessed on an individual basis. Never construct a wall if there is uncertainty regarding the stability of
an installation or the load holding capabilities. If there are doubts on a system’s viability, consult Barco for advise on pro(4x6essional
rigging organizations.
Example of a support structure
The support structure below example is pure illustrative for a H5 x V4 TF-10 display. Several variants of sup-
port structures are possible for the same size of a TF-10 display. Contact Barco for more information.
Image 2-1
It’s recommended to integrate a service platform in the support structure. Such a platform allows a fast and
easy intervention, if required.
C
AUTION
:
A lot of energy is transferred into heat, which requires a certain amount of air
fl
ow at the rear of
the TF-10 display. For that suf
fi
cient free space should be available behind the display to ensure a good ven-
tilation. The higher the display the more free space is required.
10
R59770682 FIXED TF-10 DISPLAY 23/11/2011
Summary of Contents for TF-10
Page 1: ...Fixed TF 10 display Installation Manual R59770682 02 23 11 2011 ...
Page 4: ......
Page 6: ...Table of contents 2 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Page 12: ...1 Safety 8 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Page 30: ...3 Components of a fixed TF 10 display 26 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Page 40: ...4 Physical installation 36 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Page 46: ...5 Cabling of an TF 10 display 42 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Page 56: ...7 Specifications 52 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...