background image

1. Safety Warnings

1. SAFETY WARNINGS

1.1 Safety warnings during installation

Who may install

The installation must be performed by authorized technical personnel only.

Authorized technical personnel: persons having appropriate technical training and experience necessary to be aware of hazards to
which they are exposed in performing a task and of measures to minimize the danger to themselves or other persons.

Caution risk of electric shock

Before attempting to remove any of the projector’s covers, the projector has to be turned off and disconnected from the wall outlet
to minimize the risk of electric shock.

Caution on head

Before starting with the replacement of the lamp unit, always let cool down the projector after operation in order to reduce the heat
on parts in the light path and to avoid burns.

Warning eye damage

Eye damage may result from direct viewing the light produced by the lamp used in this equipment. Always turn off lamp before
opening cover.

1.2 Product care

Installation Kit

The universal lamp replacement Kit

R9841810

is designed for use ONLY with the BARCO SLM G8/R8, G10/R10, R9+ and R12+

series projectors.

Replacement parts

When replacement parts are required, be sure the service technician has used original Barco replacement parts or authorized re-
placement parts which have the same characteristics as the Barco original part.

Unauthorized substitutions may result in degraded performance and reliability, fire, electric shock or other hazards. Unauthorized
substitutions may void warranty.

Repairable

Under no circumstances are Barco parts repairable by anyone other than Barco.

R5976544 UNIVERSAL LAMP REPLACEMENT KIT 04/01/2005

1

Summary of Contents for R9841810

Page 1: ...Universal Lamp Replacement Kit Installation manual For SLM 8 10 and R9 R12 projectors R9841810 R5976544 02 04 01 2005...

Page 2: ...Barco nv Events Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail events barco com Visit us at the web www barco com Printed in Belgium...

Page 3: ...tion in order to reduce the heat on parts in the light path and to avoid burns Warning eye damage Eye damage may result from direct viewing the light produced by the lamp used in this equipment Always...

Page 4: ...1 Safety Warnings 2 R5976544 UNIVERSAL LAMP REPLACEMENT KIT 04 01 2005...

Page 5: ...g a decrease in light output during the run time of the lamp ONLY a realignment following the Z axis can solve the light output decrease B A Image 2 1 Spacers lock nut removal Only for transport purpo...

Page 6: ...2 Introduction 4 R5976544 UNIVERSAL LAMP REPLACEMENT KIT 04 01 2005...

Page 7: ...ssary tools A flatblade screwdriver of 5 mm Removing the side panel 1 Turn with a screwdriver the side panel lock screw A a quarter turn counter clockwise A Image 3 1 Unlocking the side cover 2 Pull t...

Page 8: ...Sliding out the lamp unit 1 Loosen the 3 spacer screws A on the lamp house A B A A Image 3 3 Loosening the spacer screws 2 Using the provided handle B pull the lamp unit out of the projector frame B...

Page 9: ...xt slide the lamp unit into the projector frame Necessary tools Flatblade screwdriver of 5mm or Nut driver 8mm Installing the lamp unit 1 Remove the lock nut B on the 3 spacer screws A B A Image 4 1 2...

Page 10: ...lancing the light intensity are FACTORY PREADJUSTED Consequently both ad justable screws are anchored by a lock screw and sealed with a warranty label Destroying the label void the warranty ONLY the O...

Page 11: ...ure on PROJECTOR WHITE 3 Enter the INSTALLATION MODE and select Internal Patterns Finally set Internal patterns on PURITY 4 Enter the SERVICE MODE and select Add Ins Finally set CLO on INACTIVE 5 Loos...

Page 12: ...he side panel 1 Move the cover guides under the back cover and push the front of the cover against the projector frame lining up the cover lock screw with the speed nut A on the frame Image 4 6 Mounti...

Reviews: