Service Mode
7-11
5975977A BARCODATA 708 260597
A warning, permanent BOOST mode in use, will be displayed to
inform the user.
When text is on, this warning will be repeated every time a new
source is selected.
I2C Diagnostics
Highlights 'I2C Diagnostics' by pushing the control disk up or down
and press
ENTER.
The I2C diagnostics menu gives an overview of the I2C failures
inside the projector.
To scroll through the failure list, push the control disk up or down.
The I2C address, IC number and module name will be given in I2C
diagnostic menu.
When no errors are detected, the following message will appear on
the screen :
"No errors on i2c-bus detected".
WARNING
PERMANENT
BOOST MODE
IN USE !
Select with or
then <ENTER>
<EXIT> to return.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
Scroll with or
then <ENTER>
<EXIT> to return.
I2C DIAGNOSTICS
Failures :
addr
IC number
mod.name
48H
IC200
DECODER