background image

Safety Instructions

1-1

5975198 RETRODATA 808s 210397

WARNING

TO PREVENT FIRE OR ELECTRICAL SHOCK

HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE

FEDERAL COMMUNICATION COMMISSION (FCC STATEMENT)

This equipment has been tested and found to comply with the limits
of a class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commer-
cial environment.  This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications.  Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.

Note :
The use of shielded cables is required to comply within the limits of
Part 15 of FCC rules and EN55022.

* All the safety and operating instructions should be read before using

this unit.

* The safety and operating instructions manual should be retained for

future reference.

* All warnings on the equipment and in the documentation manuals

should be adhered to.

* All instructions for operating and use of this equipment must be

followed precisely.

On safety

1. This product should be operated from an  AC power source.

This projector may be connected to an IT-power system.

Operating AC power voltage of the projector:

BARCO RETRODATA 808s

Art.No. R9002110 (230V AC)

Art. No R9002119 (120V AC)

Consult your dealer to switch over from 230Vac to 120 Vac or from
120Vac to 230 Vac.
If you are not sure of the type of AC power available, consult your
dealer or local power company.

2. This product is equipped with a 3-wire grounding plug, a plug
having a third (grounding) pin. This plug will only fit into a grounding-
type power outlet. This is a safety feature. If you are unable to insert
the plug into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the purpose of the grounding-type
plug.

WARNING FOR THE CUSTOMERS: THIS APPARATUS MUST BE
GROUNDED  (EARTHED)  via the supplied 3 conductor AC power
cable.
(If the supplied power cable is not the correct one, consult your
dealer.)

1

SAFETY INSTRUCTIONS

Notice on Safety

This equipment is built in accordance with the requirements of the
international safety standards EN60950, UL 1950 and CSA C22.2
No.950, which are the safety standards of information technology
equipment including electrical business equipment.

These safety standards impose important requirements on the use of
safety critical components, materials and isolation, in order to protect
the user or operator against risk of electric shock and energy  hazard,
and having access to live parts.
Safety standards also impose limits to the internal and external
temperature rises, radiation levels, mechanical stability and strength,
enclosure construction and protection against the risk of fire.

Simulated single fault condition testing ensures the safety of the
equipment to the user even when the equipment's normal operation
fails.

INSTALLATION INSTRUCTIONS

Before operating this equipment please read this manual

thoroughly, and retain it for future reference.

Installation and preliminary adjustments should be performed

by qualified BARCO personnel or by authorized BARCO

service dealers.

OWNER’S RECORD

The part number and serial number are located at the back side of the
projector. Record these numbers in the spaces provided below.
Refer to them whenever you call upon your BARCO dealer regarding
this product.

PART NUMBER :

SER. NUMBER :

DEALER :

The lightning flash with an arrowhead within a
triangle is intended to tell the user that parts
inside this product may cause a risk of electrical
shock to persons.

The exclamation point within a triangle is in-
tended to tell the user that important operating
and/or servicing instructions are included in the
technical documentation for this equipment.

Summary of Contents for R9002110

Page 1: ...BARCO PROJECTION SYSTEMS Date 210397 Art No R5975198 R9002110 R9002119 INSTALLATION MANUAL RETRODATA 808s...

Page 2: ...manual is subject to change without notice Produced by BARCO NV March 1997 All rights reserved Trademarks are the rights of their respective owners Printed in Belgium BARCO nv Projection Systems Noor...

Page 3: ...ctor 5 4 Source Connection 6 1 Signal input connection on the projector 6 1 Connecting a composite video source to port 1 6 1 Connecting a S Video or Video source to port 2 6 2 Connecting a RGB Analog...

Page 4: ...fety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMER...

Page 5: ...he power cord or plug is damaged or frayed b If liquid has been spilled into the equipment c If the product has been exposed to rain or water d If the product does not operate normally when the operat...

Page 6: ...and place them on floor Save the original shipping cartons and packing material they will come in handy if you ever have to ship your retroprojector For maximum protection repack your projector as it...

Page 7: ...5198 RETRODATA 808s 210397 Projector dimensions in mm 60 42 1535 mm 54 03 1370 mm 52 81 1341 5 mm 39 21 996 mm 29 43 747 mm 29 25 743 mm 2 74 70 mm 40 10 1020 mm 0 85 22 mm 39 25 997 mm 77 53 1969 mm...

Page 8: ...order to avoid any damage of the screen surface Lift up the mirror cabinet and place it on the projector cabinet Both centering pins on the the mirror cabinet must match the centering holesintheproje...

Page 9: ...5198 RETRODATA 808s 210397 Mounting the side profiles The side profiles are packed during transportation inside the mirror cabinet back side Turn in the screws a little and slide the profile over the...

Page 10: ...of the controller module by loosening both retaining screws of the metal protection plate Pivot this plate downside image 2 1 2 The DIP switches are located on the back side of this metal protection...

Page 11: ...e projector s address may be set to any value between 0 and 255 When the address is set the projector can be controlled now by RCU for addresses between 0 and 9 IBM PC or compatible or Apple MAC for a...

Page 12: ...an address even when the displayed address is correct Use the numeric keys to enter the address 1 2 3 4 5 6 7 8 0 1 OFF ON 1 2 3 4 5 6 7 8 ON OFF Power up mode OFF ON Power up mode The projector can s...

Page 13: ...eeded to enter the adjustment mode Position of DIP Switch No 5 ON password mode enabled OFF password mode disabled baud rate code speed 0 110 1 150 2 300 3 600 4 1200 5 2400 6 4800 7 9600 More informa...

Page 14: ...r plug proceed as follows The yellow green wire is ground and must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or colored yellow and green Th...

Page 15: ...ins power input of 230 Vac The RETRODATA 808s R9002049 leaves the factory to operate on a mains power input of 120 Vac Adaptation of the power input of the projector between 230 Vac and 120Vac or vice...

Page 16: ...til service position 2 is reached The fixation points will automatically jump into the correct position when turning the frame to this position Openthecoverplateoftheelectronics frontsideoftheretropro...

Page 17: ...er mains switch on the local keyboard to switch the projector ON and OFF if the switch is pressed ON if the switch is Not pressed OFF The projector can be started up in the operational mode image disp...

Page 18: ...ng the warm up period every 30 seconds a text box with the remaining time will be displayed on the screen for 2 seconds This text box will be displayed every time on another place If a key other than...

Page 19: ...ng the loop through Video output then set the Termination Switch to the OFF position Composite video signals from a VCR OFF air signal decoder etc to next projector or to a monitor PORT 4 5 See inst a...

Page 20: ...tting is not correct start up the adjustment mode by pushing on the ADJUST key Select Random Access and press ENTER Note When using the Port 2 loop through output set the Termina tion Switch in the OF...

Page 21: ...ference that may cause undesired operation RS232 IN RS232 OUT IR REMOTE RS232 IN RS232 OUT IR REMOTE EXTER NAL IN TERNA L L R R L R L L R PORT 4 5 PORT 2 INP INP R G B H V INPUT ANALOG INTERF 120MHz O...

Page 22: ...ndesired operation RS232 IN RS232 OUT IR REMOTE RS232 IN RS232 OUT IR REMOTE EXTER N AL INT ERN A L L R R L R L L R PORT 4 5 PORT 2 INP INP R G B H V INPUT ANALOG INTERF 120MHz ON OFF inver 75 ohm ter...

Page 23: ...REMOTE RS232 IN RS232 OUT IR REMOTE EXTERNAL INTERNAL L R R L R L L R PORT 4 5 POR T 2 Audio VCR HDTV player To select the component video input with the RCU or the build in RCU press digit button 8 C...

Page 24: ...nal connected speakers PERIPHERAL EQUIPMENT Connecting a RCVDS 05 switcher to the retroprojector Up to 20 inputs with the RCVDS 05 switcher and up to 90 inputs when 10 RCVDS switchers are linked via t...

Page 25: ...NG CONTR MODULATION SOFT EDGE Orbiting Mode Toggle Switches The orbiting module is provided with a three pin connector for connection with the BARCO s BCl link option module used in multiple projector...

Page 26: ...g mode set to OFF This alignment must be performed in case of a multiple projector installation with Master and Slave projectors in order to ensure a correct operation of the Orbiting for all projecto...

Page 27: ...n adjusting the horizontal and the vertical deviation the picture moves in corresponding direction allowing the set up of the deviation without orbiting operation EXIT to return SLAVE ORBITING CHANGE...

Page 28: ...lecting the G2 adjustment menu these green LEDs must be out If not follow the next procedure to adjust the G2 open the metal cover on the lens side covering the modules by turning out the retaining sc...

Page 29: ...tory preset To carry out the Blue Gamma Correction Push the control stick forward or backward to highlight the item BLUE GAMMA CORRECTION in the menu and then press ENTER If EXIT is pressed the projec...

Page 30: ...adjust the Blue Midlights a text box with a bar scale 0 16 will be displayed to visualise the magnitude of the correction Press ENTER to return to the Gamma Corrections menu GAMMA CORRECTIONS BLUE GAM...

Page 31: ...AL FIRE PROTECTION ASSOCIATION STD 704M SIGNAL TRESHOLD LIMIT VALUE Units TRESHOLD LIMIT VALUE Units BASE METAL ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS MATERIAL SAFETY D...

Page 32: ...OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF VENDOR ASSUMES NO RESPONSABILITY FOR INJURY TO VENDEE OR THIRD PERSONS PROXIMATELY CAUSED BY THE MATERIAL IF REASONABLE SAFETY PROCEDURES ARE NOT ADH...

Page 33: ...i 1 5975198 RERODATA 808s 210397 P RCU INPUT SOURCES 1 PROJECTOR RCVDS 2 3 4 5 6 1 2 3 5 6 7 8 9 10 INPUT SOURCES 7 P RCU INPUT SOURCES 1 PROJECTOR RCVDS 2 3 4 5 6 1 2 3 5 6 7 8 9 10 INPUT SOURCES 7...

Reviews: