background image

Safety Instructions

1-1

5976002 RETROGRAPHICS 808S 100299

WARNING

TO PREVENT FIRE OR ELECTRICAL SHOCK

HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE

FEDERAL COMMUNICATION COMMISSION (FCC STATEMENT)

This equipment has been tested and found to comply with the limits

of a class A digital device, pursuant to Part 15 of the FCC Rules.  These

limits are designed to provide reasonable protection against harmful

interference when the equipment is operated in a commercial

environment.  This equipment generates, uses and can radiate radio

frequency energy and, if not installed and used in accordance with

the instruction manual, may cause harmful interference to radio

communications.  Operation of this equipment in a residential area is

likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.

Note :

The use of shielded cables is required to comply within the limits of

Part 15 of FCC rules and EN55022.

* All the safety and operating instructions should be read before using

this unit.

* The safety and operating instructions manual should be retained for

future reference.

* All warnings on the equipment and in the documentation manuals

should be adhered to.

* All instructions for operating and use of this equipment must be

followed precisely.

On safety

1

. This product should be operated from an  AC power source.

  This projector may be connected to an IT-power system.

Operating AC power voltage of the projector:

BARCO RETROGRAPHICS 808s

Art.No. R9002041 (

230V AC

)

Art. No R9002048 

(120V AC)

Consult your dealer to switch over from 230Vac to 120 Vac or from

120Vac to 230 Vac.

If you are not sure of the type of AC power available, consult your

dealer or local power company.

2

. This product is equipped with a 3-wire grounding plug, a plug

having a third (grounding) pin. This plug will only fit into a grounding-

type power outlet. This is a safety feature. If you are unable to insert

the plug into the outlet, contact your electrician to replace your

obsolete outlet. Do not defeat the purpose of the grounding-type plug.

WARNING FOR THE CUSTOMERS

: THIS APPARATUS MUST BE

GROUNDED  (EARTHED)  via the supplied 3 conductor AC power

cable.

(If the supplied power cable is not the correct one, consult your

dealer.)

A. Mains lead  (Power cord) with CEE 7 plug

:

The wires of the mains lead are colored in

accordance with the following code.

Green and yellow:earth (safety earth)

Blue:

neutral

Brown:

line (live)

1

SAFETY INSTRUCTIONS

Notice on Safety

This equipment is built in accordance with the requirements of the

international safety standards EN60950, UL 1950 and CSA C22.2

No.950, which are the safety standards of information technology

equipment including electrical business equipment.

These safety standards impose important requirements on the use

of safety critical components, materials and isolation, in order to

protect the user or operator against risk of electric shock and energy

hazard, and having access to live parts.

Safety standards also impose limits to the internal and external

temperature rises, radiation levels, mechanical stability and strength,

enclosure construction and protection against the risk of fire.

Simulated single fault condition testing ensures the safety of the

equipment to the user even when the equipment's normal operation

fails.

INSTALLATION INSTRUCTIONS

Before operating this equipment please read this manual

thoroughly, and retain it for future reference.

Installation and preliminary adjustments should be

performed by qualified BARCO personnel or by author-

ized BARCO service dealers.

OWNER’S RECORD

The part number and serial number are located at the back side of the

projector. Record these numbers in the spaces provided below.

Refer to them whenever you call upon your BARCO dealer regarding

this product.

PART NUMBER :

SER. NUMBER :

DEALER :

The lightning flash with an arrowhead within a

triangle is intended to tell the user that parts inside this

product may cause a risk of electrical shock to

persons.
The exclamation point within a triangle is intended to

tell the user that important operating and/or servicing

instructions are included in the technical documen-

tation for this equipment.

Summary of Contents for R9002041

Page 1: ...BARCO PROJECTION SYSTEMS Date 100298 Art No R5976002 R9002041 R9002048 INSTALLATION MANUAL RETROGRAPHICS 808s Revision 00...

Page 2: ...y BARCO NV February 1999 All rights reserved Trademarks are the rights of their respective owners Printed in Belgium BARCO n v Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368211 Fax...

Page 3: ...s voltage adaptation 5 2 Switching on the projector 5 4 Source Connection 6 1 Signal input connection on the projector 6 1 Connecting a composite video source to port 1 6 1 Connecting a S Video or Vid...

Page 4: ...eplace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMERS THIS APPARATUS MUST BE GROUNDED EARTHED via the supplied 3 conductor AC power cable If the su...

Page 5: ...i reflective coating therefore avoid touching the lens To remove dust on the lens use a soft dry cloth Do not use a damp cloth detergent solution or thinner On repacking Save the original shipping car...

Page 6: ...and place them on floor Save the original shipping cartons and packing material they will come in handy if you ever have to ship your retroprojector For maximum protection repack your projector as it...

Page 7: ...Unpacking and dimensions 2 2 5976002 RETROGRAPHICS 808s 100299 Projector dimensions in mm...

Page 8: ...r to avoid any damage of the screen surface Lift up the mirror cabinet and place it on the projector cabinet Both centering pins on the the mirror cabinet must match the centering holes in the project...

Page 9: ...n the screws a little and slide the profile over the screws Fixate the 3 screws Unfolding the mirror house To unfold the mirror house handle as follow 1Unlock the mirror cabinet by pushing the bracket...

Page 10: ...ion set up 3 3 5976002RETROGRAPHICS808s100299 Closing the mirror house Toclosethemirrorhousing unlockthepinlockonbothsidesandpush the mirror house to the front until it clicks into the transportation...

Page 11: ...r of the controller module by loosening both retaining screws of the metal protection plate Pivot this plate downside image 2 1 2 The DIP switches are located on the back side of this metal protection...

Page 12: ...tting the projector address The projector s address may be set to any value between 0 and 255 When the address is set the projector can be controlled now by RCU for addresses between 0 and 9 IBM PC or...

Page 13: ...ssary to enter an address even when the displayed address is correct Use the numeric keys to enter the address 1 2 3 4 5 6 7 8 0 1 OFF ON 1 2 3 4 5 6 7 8 ON OFF Power up mode OFF ON Power up mode The...

Page 14: ...needed to enter the adjustment mode Position of DIP Switch No 5 ON password mode enabled OFF password mode disabled baud rate code speed 0 110 1 150 2 300 3 600 4 1200 5 2400 6 4800 7 9600 More infor...

Page 15: ...ug proceed as follows The yellow green wire is ground and must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or colored yellow and green The bl...

Page 16: ...mains power input of 230 Vac The RETROGRAPHICS 808s R9002048 leaves the factory to operate on a mains power input of 120 Vac Adaptation of the power input of the projector between 230 Vac and 120Vac o...

Page 17: ...2 is reached The fixation points will automatically jump into the correct position when turning the frame to this position Openthecoverplateoftheelectronics frontsideoftheretroprojector by loosening...

Page 18: ...ard to switch the projector ON and OFF if the switch is pressed ON if the switch is Not pressed OFF The projector can be started up in the operational mode image displayed or in the stand by mode depe...

Page 19: ...the warm up period every 30 seconds a text box with the remaining time will be displayed on the screen for 2 seconds This text box will be displayed every time on another place If a key other than th...

Page 20: ...ld in RCU press digit button 1 Note if using the loop through Video output then set the Termination Switch to the OFF position Composite video signals from a VCR OFF air signal decoder etc 56 1 56 287...

Page 21: ...DOUBLER ON Highlight Picture Tuning and press ENTER Select Selected source and press ENTER Input selection with the RCU or the local keyboard press digit button 2 Depending on the priority setting in...

Page 22: ...Termination Resistors and Switches When changing a switch position or removing a resistor turn off the projector and unplug the power cord from the wall outlet 75 W Termination resistors In case of c...

Page 23: ...detection with the RCU or the build in RCU press digit button 4 or 5 Connecting a RGB Analog source with Tri level 56 1 56 2875 5 02 7 5 5 PORT 4 5 PORT3 COMM PORT PORT1 PROJECTORMODE POWER MAINS inv...

Page 24: ...a Component Video source with Tri 56 1 56 2875 5 027 5 5 PORT 4 5 PORT3 COMM PORT PORT1 PROJECTORMODE POW ER MAINS with the RCU or the build in RCU press digit button 8 Connecting external loudspeake...

Page 25: ...stereo sound will be lost Speaker selection switch To switch between internal loudspeakers or external loudspeakers When pressed set for operation with sound output from the built in speaker system Wh...

Page 26: ...ORBITING CONTR MODULATION SOFT EDGE Orbiting Mode Toggle Switches The orbiting module is provided with a three pin connector for connection with the BARCO s BCl link option module used in multiple pro...

Page 27: ...biting mode set to OFF This alignment must be performed in case of a multiple projector installation with Master and Slave projectors in order to ensure a correct operation of the Orbiting for all pro...

Page 28: ...ss ENTER When adjusting the horizontal and the vertical deviation the picture moves in corresponding direction allowing the set up of the deviation without orbiting operation EXIT to return SLAVE ORBI...

Page 29: ...g the G2 adjustment menu these green LEDs must be out If not follow the next procedure to adjust the G2 open the metal cover on the lens side covering the modules by turning out the retaining screws o...

Page 30: ...factory preset To carry out the Blue Gamma Correction Push the control disc forward or backward to highlight the item BLUE GAMMA CORRECTION in the menu and then press ENTER If EXIT is pressed the proj...

Page 31: ...adjust the Blue Midlights a text box with a bar scale 0 16 will be displayed to visualise the magnitude of the correction Press ENTER to return to the Gamma Corrections menu GAMMA CORRECTIONS BLUE GA...

Page 32: ...AL FIRE PROTECTION ASSOCIATION STD 704M SIGNAL TRESHOLD LIMIT VALUE Units TRESHOLD LIMIT VALUE Units BASE METAL ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS MATERIAL SAFETY D...

Page 33: ...ATA OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF VENDORASSUMESNORESPONSABILITYFORINJURYTOVENDEEORTHIRDPERSONSPROXI MATELY CAUSED BY THE MATERIAL IF REASONABLE SAFETY PROCEDURES ARE NOT AD HERED...

Reviews: