background image

To replace the lamp:

1. Unplug the power cord from the outlet or appliance 

inlet.

2. Loosen two screws (a) on the rear and two screws 

(b) on the side that are securing the side cover (c) 
using a Phillips screwdriver.

(c)

(b)

(a)

3. Slide and remove the side cover towards the rear.

4. Loosen two screws (d) that are securing the lamp 

cover using a Phillips screwdriver and remove the 
lamp cover (e) from the projector.

(e)

(d)

5. Loosen two screws (f) that are securing the lamp 

box to be removed using a Phillips screwdriver.

LAMP 2

LAMP 1

(f)

(f)

6. Pull the handle.
7. Pull out the lamp box by the handle while holding 

the projector.

•  Pull the lamp box out of the projector slowly. 

When the lamp is broken, glass fragments may 
be scattering by quickly pulling out the lamp box.

•  Do not spill liquid on the removed lamp box or 

do not place it near any flammable object or 
where children can reach to prevent injury or fire.

8. Load a new lamp box securely into the projector in 

the right orientation.

9. Put the handle back to the original position.

•  Make sure that the handle is locked.

Warning:

•  Be careful not to drop the lamp 

 screws into 

the inside of the projector. Don’t put a metal piece 

or flammable object into the projector. Using the 

projector with any foreign object present inside 

may result in electric shock or fire. When you can’t 

remove the foreign object from the inside, contact 

your dealer for removal. 

•  Do not touch the lamp with bare hands or give 

a shock to the lamp. Attach the lamp properly. 
Improper handling may cause explosion.

•  Be sure to install the lamp securely. When the lamp 

isn’t installed properly, it won’t illuminate. Improper 

installation may also result in fire.

•  Don’t shake the removed lamp or don’t lift it above 

your face. You may be injured in your eye by flying 

or falling glass fragments.

•  Don’t replace the lamp immediately after use 

because the lamp cover is very hot. You may get 

burned. Turn off the power using the POWER key. 

After the lamp goes out, wait about 2 minutes until 

the intake and exhaust fans for cooling the lamp 
stop rotating. Then unplug the power cord, and 
wait at least 1 hour to allow the lamp to cool down 
enough to the touch.

Before replacing the lamp

1. Check which lamp is to be replaced using the INFO 

menu in the OSD Lite menu.

H LAMP 350W

Replacement Manual

Spare lamp

Reviews: