1. Safety
LED components used in OLite devices are ESD (Electro-Static Discharge) sensitive. To prevent the possibility of destroying LED
components do not touch either in operation or while switched off.
Risk of electric shock / Risk of fire:
To protect against risk of fire by overloading of power cables, MAXIMUM 2 TILES may be
connected in parallel. Each power source cable supplying MAXIMUM 2 TILES should be protected by a circuit breaker or fuses
rated 16 A / 250 VAC (15 A / 250 VAC in the USA and Canada).
Disconnect device:
When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall be installed near the
equipment and be easily accessible, or a readily accessible general disconnect device shall be incorporated in the fixed wiring.
This equipment MUST be earthed:
In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding
type plug will expose you to the risk of electric shock.
Power system:
It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in order to avoid large ground currents loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriate rated disconnect switch, circuit breakers and Ground Fault Current Interrupters.
The installation shall be done according to the local electrical installation codes. In Europe special attention should be given to EN
60364, the standard for electrical installation of buildings. In Germany VDE 0100 should be adhered to.
Mains cords:
The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power cords are
damaged, replace only with new ones. Never try to repair a power cord.
Data cables:
The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cables are
damaged, replace only with new ones. Never try to repair a data cable. Per requirements of the National Electrical Code® in the
USA , the length of a data cable must not exceed 42 m (140 feet). Avoid exposure of data cables to accidental contact with lightning
or power conductors.
1.4 Important warnings concerning flight cases
Important warnings concerning stack and transport OLite rental flight cases
•
Maximum stack two (2) OLite rental flight cases high. Never higher.
•
Surface on which flight case is standing must be level to ensure that the total load is evenly spread out among the four wheels.
The surface must also be able to support the load safely.
•
Before stacking or transporting flight cases, check the wheels and their fixation screws for wear or defects.
•
Before stacking or transporting flight cases, check that the OLite rentals are securely locked into the base of the flight case.
•
Before stacking or transporting flight cases, check the four lock handles on each flight case are in good working order and
locked securely.
•
When stacked, make sure the wheels of the upper flight case are precisely positioned in the stacking dishes of the flight case
below.
•
Stacked flight cases may not be moved. Before stacking, the lower flight case must already be in its final resting position before
placing the second upon it.
•
Never stack loaded flight cases in a truck or other transport medium, unless each flight case is rigidly strapped tight.
•
In the event of a wheel breaking, flight cases must be rigidly strapped tight to prevent a stack collapsing.
•
Use an appropriate forklift to raise flight cases and take the necessary precautions to avoid personnel injury.
R5976832 OLITE RENTAL DISPLAY 15/12/2004
5
Summary of Contents for OLite 510
Page 1: ...OLite rental display Installation manual R5976832 00 15 12 2004...
Page 4: ......
Page 10: ...1 Safety 6 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 12: ...2 Installation requirements 8 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 14: ...3 System overview 10 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 22: ...4 Components of an OLite rental tile 18 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 46: ...7 Basic set up procedures 42 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 52: ...8 Cabling of an OLite rental display 48 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 54: ...9 Maintenance 50 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 64: ...A Dimensions 60 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 70: ...C Order info 66 R5976832 OLITE RENTAL DISPLAY 15 12 2004...