87
R5913593 /01
Njord
7.4 Communication connections
Communication Panel
3
2
1
4
5
6
7
8
9
10
11
12
13
Image 7
–
5
1
WIFI antenna for wireless IP (optional)
2
12V 1A output
3
Firmware update / USB download log files
4
10/100 base-T for external control over IP and Art-Net
5
DMX interface input
6
DMX interface output
7
XLR input for wired projector control
8
RS232 for serial communication
9
Sync Out 3D
10
Sync In 3D
11
Status lights
12
IR receive sensor
13
GSM antenna input (optional)
CAUTION:
Ethernet should only be connected to either the 10/100 base-T port (on the
communication panel) or the HDBaseT input (on the Quad Combo Input Mk II). Using both at the
same time will lead to undefined behavior.
12 V output
12 V output, maximum 1 A, available when projector is not in stand by.
DMX interface
DMX is used as communication bus between different devices in the light technic. Each device has an input
and an output, so that the bus can be looped between the different devices. According the standard a five wire
cable with XLR connector is used.
You can use the DMX input port to connect a DMX device (DMX console) to the projector. This way you can
control the projector from that DMX device (console). The DMX output port can be connected with the next
device in the loop.
DMX
Pin
Description
1
Earth
2
Cold
3
Hot
4
Return - (or not used)
5
(or not used)
DMX
DMX-512 Lighting protocol over RS-485 interface. Carries information of 512 channels from a
lighting controller to lighting devices. Standardized by USITT.
RS232/RS422 input
The communication interface of the NJORD series projector supports RS232 and RS422 serial
communication on two different types of input connectors, a Sub-D connector and an USB connector acting as
RS input when connected to an USB input of a PC.
You can use the RS232/RS422 input to connect a local PC to your NJORD series projector. By this way you
can configure and control your projector from your local PC.
Summary of Contents for Njord
Page 1: ...ENABLING BRIGHT OUTCOMES Installation Manual Njord...
Page 24: ...R5913593 01 Njord 24 Installation process...
Page 35: ...35 R5913593 01 Njord 360 360 Image 3 9 Prepare to install...
Page 40: ...R5913593 01 Njord 40 Prepare to install...
Page 68: ...R5913593 01 Njord 68 Getting Started...
Page 82: ...R5913593 01 Njord 82 Pulse Remote Control Unit...
Page 108: ...R5913593 01 Njord 108 GUI Image...
Page 109: ...109 R5913593 01 Njord Advanced picture adjustments 10...
Page 156: ...R5913593 01 Njord 156 12 2 IR control GUI System Settings...
Page 178: ...R5913593 01 Njord 178 GUI System Settings...
Page 182: ...R5913593 01 Njord 182 GUI Status menu...
Page 186: ...R5913593 01 Njord 186 Flight case and rigging frame...
Page 192: ...R5913593 01 Njord 192 Pulse SFP input use cases...
Page 198: ...R5913593 01 Njord 198 Projector covers...
Page 199: ...199 R5913593 01 Njord Product maintenance 17...
Page 202: ...R5913593 01 Njord 202 Product maintenance...
Page 203: ...203 R5913593 01 Njord Risk group 3 Safety 18...
Page 210: ...R5913593 01 Njord 210 Risk group 3 Safety...
Page 211: ...211 R5913593 01 Njord Input specifications A...
Page 218: ...R5913593 01 Njord 218 Input specifications...
Page 222: ...R5913593 01 Njord 222 B 3 DMX chart Extended DMX chart...
Page 228: ...R5913593 01 Njord 228 Index...
Page 230: ...R5913593 01 Njord 230 List of tools...
Page 231: ......