MRDS specifications
www.barco.com/defense
September 2007
The information and data given are typical for the equipment described.
However any individual item is subject to change without any notice.
The latest version of this product sheet can be found on www.barco.com.
Functionality
MRDS-1
MRDS-2
CPU/Speed
Configuration 1: Intel
®
Intel
®
Pentium
®
M
®
, 2.0 GHz
Pentium
®
M
®
, 1.1 Ghz
Configuration 2: Intel
®
Pentium
®
M
®
, 1.6 Ghz
Max RAM
Configuration 1: 512 MB
1 GB (DDR2 SDRAM)
(DDR SDRAM)
Configuration 2: 512 MB or
1024 MB (DDR SDRAM)
Max Graphics Resolution
1600x1200
1920x1200
OS
Windows XP Pro, Xpe, Linux
Windows XP/Linux
Standard I/O
4 x serial ports, 2x Ethernet
1x 1000/100/10 Ethernet,
10/100 BASE TX, 4xUSB 2.0,
2x RS-232, Audio Line In,
2 x PS2, 2x Audio Out line,
Audio Line Out, Microphone In,
1x Micro In line
6x USB 2.0
Additional I/O
4 x serial ports, 2x USB 2.0,
N/A
1 x Gigabit Ethernet,
2xIEEE1394, 1 x SCSI
Hard disk module
20 GB and 30 GB
16 GB Solid State IDE Drive
Compact Flash Memory
Up to 8 GB
N/A
Expansion Slots
PMC and PC-104+
1x PCI
Direct Video Input
3x CVBS (PAL/NTSC) sources
3x NTSC/PAL Common Sense API
or 1x S-Video
Color keying/transparency
Windowing/Full screen
Power Supply
28 VDC (115 VAC optional)
28 VDC
UPS
4 minutes autonomy,
N/A
allowing proper shutdown
Sensitive Data Erase Function
Optional
Optional
Display interface
Direct drive to Barco displays
Direct drive to Barco displays
10” to 21“ Dual-Head option
10” to 21”, Dual-head standard.
Environmental
MRDS-1 air cooled
MRDS-1 sealed
MRDS-2
Low Operating Temperature
0°C/+32°F
-25°C/-13°F
-20°C Continuous Operating
(MIL-STD-810E)
High Operating Temperature
+55°C/+131°F
+55°C/+131°F
+71°C Continuous Operating
(MIL-STD-810E)
Humidity
MIL-STD-810E,
MIL-STD-810E,
MIL-STD-810F Method 507.4 –
95% @ 40°C
95% @ 40°C
Figure 507.4.1
Shock
MIL-STD-810E
MIL-STD-810E,
MIL-STD-810F Method 516.5,
30g - 12.5 ms half sine
40g X and Y axis,
Procedure 1 40g shock
60g Z axis 16.5 ms
15-23ms duration, half sine
MIL-S-901D optional
Vibration
MIL-STD-167-1/MIL-E-5400T, 2g
MIL-STD-167-1/MIL-E-5400T, 5g
MIL-STD-810E, Tracked Vehicle
Altitude – operating
MIL-STD-810E, 10,000 ft
MIL-STD-810E, 21,000 ft
MIL-STD-810F, Method 500.4
(with flash technology option)
Proc II – 35,000 ft (238 mbar)
Altitude – storage
MIL-STD-810E, 25,000 ft
MIL-STD-810E, 40,000 ft
MIL-STD-810F, Method 500.4
Proc I – 40,000 ft (188 mbar)
Drip-proofness
45°
Water proof
Sealed
Fungus Insertion
-
compliant
MIL-STD-810F Method 508.5
Salt fog
-
compliant
MIL-STD-810F Method 509.4
35C – 5% saline solution, 48h
Sand/Dust
-
compliant
MIL-STD-810F procedure I
EMI/EMC (MIL-STD-461E)
Surface Ships & Submarines
Ground Army
Ground Army
FCC
Class B
Class B
Class A
Safety
IEC 950 Compliant
IEC 950 Compliant
IEC 950 Compliant
Barco
Barco Federal Systems
Pres. Kennedypark 35
BarcoView-TEXEN
3059 Premiere Parkway, Suite 100
B-8500 Kortrijk, Belgium
7 Rue Roger Camboulives
Duluth, Georgia, 30097-4905, USA
Phone: +32 56 233268
BP 1226 - F-31037 Toulouse, France
Phone: +1 678 4758000
Fax: +32 56 233013
Phone: +33 5 34 637174
Fax: +1 678 4758100
Fax: +33 5 34 637020
MRDS_bro_nieuw.qxd:- 18-09-2007 09:48 Pagina 1