background image

1. Lamp House with 2.5 kW lamp

1. LAMP HOUSE WITH 2.5 KW LAMP

Purpose of the Lamp House with 2.5 kW lamp

The Lamp House with 2.5 kW lamp is exclusively designed for the Barco HDX series and can thus not be used on any other equip-
ment.

Overview

Introduction

Safety

1.1

Introduction

Order info & content of the kit

When ordering the Lamp House with 2.5 kW lamp for HDX series, refer to article number R9864130.

The table below gives an overview of the content of the kit.

Article number

Description

Quantity

Image

R5905109

This installation manual

1

image 1-1

R856950

Lamp House with 2.5 kW lamp

1

image 1-2

Image 1-1

Image 1-2

1.2

Safety

Safety instructions

Read and heed the following warnings and cautions.

W

ARNING

:

The procedures below may only be performed by Barco trained and quali

fi

ed technicians.

W

ARNING

:

The projector must be cooled down before removing any of the projector covers: wait for the cool

down cycle to

fi

nish after switching the projector to standby (the sound of the fans comes to a very low level)

and wait for 15 more minutes before starting any of the procedures below.

W

ARNING

:

Unplug the mains power supply cord in order to completely cut off the power supply to the pro-

jector. Failure to do so can cause serious injury or death.

R5905109 LAMP HOUSE WITH 2.5 KW LAMP 21/09/2011

3

Summary of Contents for Lamp House with 2.5 kW lamp

Page 1: ...Lamp House with 2 5 kW lamp Installation manual For HDX series R9864130 R5905109 02 21 09 2011 ...

Page 2: ...Barco nv Events Noordlaan 5 B 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 36 88 24 Support www barco com esupport Visit us at the web www barco com Printed in Belgium ...

Page 3: ...ior written consent of Barco Disposal Information This equipment has required the extraction and use of natural resources for its production It may contain hazardous substances for health and environment In order to avoid the dissemination of those substances in the environment and to diminish the pressure on natural resources we encourage you to use the appropriate take back systems Those systems...

Page 4: ......

Page 5: ...ouse with 2 5 kW lamp 3 1 1 Introduction 3 1 2 Safety 3 2 Lamp and Lamp House 5 2 1 Removal of the Lamp House 5 2 2 Installation of the Lamp House 6 2 3 Realignment of the lamp in the Lamp House 7 R5905109 LAMP HOUSE WITH 2 5 KW LAMP 21 09 2011 1 ...

Page 6: ...Table of contents 2 R5905109 LAMP HOUSE WITH 2 5 KW LAMP 21 09 2011 ...

Page 7: ...ge 1 1 R856950 Lamp House with 2 5 kW lamp 1 image 1 2 Image 1 1 Image 1 2 1 2 Safety Safety instructions Read and heed the following warnings and cautions WARNING The procedures below may only be performed by Barco trained and qualified technicians WARNING The projector must be cooled down before removing any of the projector covers wait for the cool down cycle to finish after switching the proje...

Page 8: ...mp House with 2 5 kW lamp CAUTION Always wear a wrist band which is connected to the ground while handling the electrostatic dis charge ESD sensitive parts 4 R5905109 LAMP HOUSE WITH 2 5 KW LAMP 21 09 2011 ...

Page 9: ...co trained and qualified technicians Necessary tools 7 mm flat screwdriver How to remove the Lamp House 1 Switch off the projector and unplug the power cord at the projector back side 2 Let the projector cool down for at least 15 minutes before proceeding to the next step Warning The Lamp House is very hot after operation Let the projector cool down for at least 15 minutes before proceeding to the...

Page 10: ...ot possible to start up the projector 2 2 Installation of the Lamp House WARNING The procedures below may only be performed by Barco trained and qualified technicians Necessary tools 7 mm flat screwdriver How to install the Lamp House 1 Take the Lamp House by its handles and gently slide it in its compartment Tip The compartment is provided with a guide to position the Lamp House correctly 6 R5905...

Page 11: ...5 Plug in the power cord at the projector back side Note While starting up the projector the electronics detect if a Lamp House is installed If no Lamp House is installed it is not possible to start up the projector 2 3 Realignment of the lamp in the Lamp House WARNING The procedures below may only be performed by Barco trained and qualified technicians It is recommended to realign the Z axis of t...

Page 12: ... 4 Switch on the projector and startup the lamp 5 Press Menu to activate the menus and select Lamp Z axis Image 2 6 Main menu lamp Image 2 7 Lamp Z axis 6 Press ENTER to display the current light output Image 2 8 Current light output 7 Release the lock nuts for the X axis Y axis and Z axis 8 Adjust the X Y and Z axis for maximum light output Carefully turn the thumbscrews in one direction and once...

Page 13: ...ge 2 9 1 X lock 2 X adjustment 3 Y lock 4 Y adjustment 5 Z lock 5 Z adjustment 10 Switch off the projector 11 Install the right projector cover See the installation manual of the projector R5905109 LAMP HOUSE WITH 2 5 KW LAMP 21 09 2011 9 ...