5. Troubleshooting
Code 6057: “Board id: light sensor module not accessible” (Error)
Situation
Solution
Only the ID parameters of the Light
Sensor Module are not accessible.
The ID parameters of all other
boards are accessible.
Ignore this error message unless other functionality of the light sensor module fails as
well. If so, replace the Light Sensor Module. See XXXX.
The Board ID of all other boards
are also NOT accessible. This
may indicates a malfunction I²C
functionality on the PMP board.
1.
Reboot the projector.
2.
Replace the PMP board. See "Replacing the PMP board", page 156.
Malfunction Light Sensor Module
(reference 3 image 5-15).
Replace the Light Sensor Module. See XXXX.
3
12
Image 5-15
Code 6058: “Board id: light sensor module read error” (Error)
Situation
Solution
Light Sensor Module disconnected.
Check if the wire unit (reference 12 image 5-15) is connected with the Light Sensor
Module and with the Power Distribution board (reference 6 image 5-13).
Malfunction Light Sensor Module.
The projector can not read from the
installed Light Sensor Module.
In case no other “board read errors” appears, replace the Light Sensor Module (CLO).
See XXXX.
Malfunction internal RS485
communication line. The FCB, MCB
and LIM also reports “read errors”.
Disconnect the boards one by one from the internal RS485 line until this error
disappears. Replace the board which makes this error goes away. See chapter XXXX,
to know which boards are using the internal RS485 communication line. If the problem
remains replace the PMP.
Code 6059: “Board id: light sensor module write error” (Error)
Situation
Solution
Malfunction Light Sensor Module.
The projector can not write to the
installed Light Sensor Module.
Replace the Light Sensor Module. See XXXXX.
Code 6060: “Board id: formatter red unknown format” (Warning)
Situation
Solution
Old projector software installed.
The ID parameters of the Formatter
board of the RED channel are written
in a format which is not known by the
projector software.
Check if the version of the installed projector software is the latest available version. The
latest version can be downloaded from
https://my.barco.com
.
Formatter board of the RED channel
has invalid
fi
rmware.
Replace the Light Processor. See "HDF Light Processor", page 189.
Corrupt projector software.
Reinstall the latest projector software.
50
R5905312 HDF W SERIES 24/01/2013
Summary of Contents for HDF W series
Page 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Page 4: ......
Page 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Page 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Page 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Page 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Page 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Page 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Page 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Page 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Page 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Page 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Page 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Page 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Page 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Page 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Page 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Page 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Page 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Page 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Page 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Page 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Page 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...