70"
OverView fDG70-DL, OverView fDR
+
70-DL
Luminance (cd/m
2
| ftL)
HVA
HVM
(
1
)
HVX
(
2
)
•
XGA
100W
95 | 28
170 | 50
425 | 125
120W
114 | 33
190 | 57
515 | 150
•
SXGA
+
100W
110 | 33
190 | 55
495 | 145
120W
125 | 40
230 | 65
560 | 165
•
Operating conditions
Rel. humidity
Up to 90% non condensing
Temperature
10°C-40°C|50°F-105°F
•
Storing conditions
0°C-40°C|32°F-105°F
Optical dimming with dynamic
feedback
A patent pending optical dimming
system in combination with a dynamic
feedback control loop results in a
uniform image across the wall and
maintains the brightness over time.
This feature allows:
•
independent brightness control of
each module without loss of contrast
or color depth
•
equal brightness, contrast and color
depth across the display wall
•
equal luminance of the display wall
across time
•
ergonomic dimming of full display
wall for day and night operation
OverView Control Manager
•
control of the wall from any place
•
graphical user interface represents the
display wall on your desktop
•
exchanges information between
display modules
•
display wall health status
•
brightness control
•
lamp overview and report
Structure
O
VER
V
IEW
fDG70-DL
O
VER
V
IEW
fDR
+
70-DL
W
1,400 mm | 55.1 inch
H
1,050 mm | 41.34 inch
R
70" nominal
D1
793 mm | 31.2 inch
D2
689,5 mm | 27.15 inch
Aspect ratio
4:3
SH (
1
)
1,288 mm | 50.7 inch
SH (
1
)
836 mm | 32.9 inch
SH min (
1
)
613 mm | 24.1 inch
(
1
) standard. Other support heights possible upon request
(
1
) Option, (
2
) on special request
Redundancy concept
•
dual lamp: 100% availability of your
display wall
•
2 modes:
Hot standby
: 2nd lamp is on, i.e. the
switching time in case of lamp failure
of the master lamp is virtually zero
Cold standby
: 2nd lamp is switched
off during operation, i.e. it will only
be activated when master lamp
failure is detected – switching takes
around 30 seconds
•
lamp change without direct operator
intervention
W
H
R
SH
D2
D1
•
hot swappable lamps: failed lamp can
be replaced while other lamp
generates image
•
lamp changes can be planned
•
lower operational costs
•
Dual DVI-D input on SXGA
+
version:
allows connection of two
simultaneous sources or controllers for
full redundancy upon failure of one
source or controller
OverView_fDG70_DL:OverView fPR-DL_brochure.qxd 17-10-2007 14:02 Pagina 4