7. Service Mode
Following parameters are displayed in the Overtemperature Settings:
Temp (in °C)
The actual temperature measured by the BARCO Duet II.
Shutdown Temp (Default set to 70°C)
When the temperature exceeds this value the Duet II will be
shut down.
Restart Temp (Default set to 46°C)
The Duet II will be switched back on again when the
temperature drops below this value.
The Shutdown Temp and Restart Temp Settings can be adjusted, however these changes or not saved, when
restarting the Duet II these values will be set back to the default settings.
W
ARNING
:
Changing these Overtemperature Settings can cause damage to the Duet II, adjusting these set-
tings is best done by a Barco Technician.
How to display (change) the Overtemperature Settings?
1. Push the cursor key
↑
or
↓
to highlight
Overtemp settings
2. Press
ENTER
to select.
The
Overtemperature Settings
menu will be displayed. (menu 7-10)
Duet II Interface
Title Screen
Change Duet Addr
Change Baudrate
Overtemp settings
AMDS settings
DVI Output limit
Software version
Please select item
Menu 7-9
Duet II Interface
Temp :
00032
Shutdown Temp 00070
Restart Temp 00046
Please select item
Menu 7-10
7.7
AMDS Settings
What is displayed?
Following parameters of the Source Signal connected to the BARCO Duet II are displayed in the AMDS Settings menu:
•
Vertical Frequency
1
•
Horizontal Time Period
•
Total Lines
•
Mono or Stereo Source
•
Stereosync (internal or external)
How to display the AMDS Settings?
1. Push the cursor key
↑
or
↓
to highlight
AMDS settings
. (menu 7-11)
2. Press
ENTER
to select.
1. Divide the value displayed in the menu by 100 to get the actual Vertical Frequency.
54
R5976550 BARCO DUET II 10/05/2007