![background image](http://html1.mh-extra.com/html/barco/dp4k-32b/dp4k-32b_service-bulletin_4079584010.webp)
Barco service bulletin
6
7
LEFT SIDE
LEFT SIDE
RIGHT SIDE
RIGHT SIDE
FORCE
FORCE
Image 1-12
Both magnets should attract to each other.
If this is not the case, switch the orientation of the magnet.
6. Place the magnet (8) back in the Lamp House.
8
LEFT SIDE
LEFT SIDE
RIGHT SIDE
RIGHT SIDE
Image 1-13
7. After correcting the orientation of the magnet the lamp arc behavior can be different. A
realignment of the lamp in its re
fl
ector is necessary. See service manual of your projector
for the detailed procedure.
InfoT: 1160
Page 10 of10