R5906848 /04
DP2K SLP Series
364
Code 20414:
“
LDM 1-6
–
Not configured (initialization failure)
”
For this error the same troubleshooting table can be applied to as for code
20279
:
“
LDM 1
–
Not configured
(initialization failure)
”
.
Code 20425:
“
LDM 1-7
–
24V LCB voltage low
”
Situation
Solution
Wiring issue
Check the cable between LCB and the 24V filter board on the one end,
and the cable between the filter board and the +24V module of the LDM
(LDM slot 7). Replace if necessary.
Malfunction 24V filter board.
Replace the 24V filter board. See service procedure
”
, page 65.
Code 20426:
“
LDM 1-7
–
24V LCB voltage high
”
For this error the same troubleshooting table can be applied to as for code
20425
:
“
LDM 1-7
–
24 V LCB
voltage low
”
.
Code 20431:
“
LDM 1-7
–
Heatsink rectifier temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20432:
“
LDM 1-7
–
Heatsink rectifier temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20433:
“
LDM 1-7
–
Heatsink rectifier temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20436:
“
LDM 1-7
–
Not configured (invalid module type)
”
For this error the same troubleshooting table can be applied to as for code
20278
:
“
LDM 1
–
Not configured
(invalid module type)
”
.
Code 20437:
“
LDM 1-7
–
Not configured (no communication)
”
Situation
Solution
Mismatch in driver boards
mounted in the LDM
Check if the +24 V module is in the correct slot (LDM 1-7).
Code 20438:
“
LDM 1-7
–
Not configured (initialization failure)
”
For this error the same troubleshooting table can be applied to as for code
20279
:
“
LDM 1
–
Not configured
(initialization failure)
”
.
Code 20523:
“
LDM 1-3
–
LLS bank 4 drain voltage too high
”
For this error the same troubleshooting table can be applied to as for code
20323
:
“
LDM 1
–
LLS bank 1 drain
voltage too high
”
.
Code 20527:
“
LDM 1-3
–
LLS bank 5 drain voltage too high
”
For this error the same troubleshooting table can be applied to as for code
20323
:
“
LDM 1
–
LLS bank 1 drain
voltage too high
”
.
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...