Situation
Solution
The TI system status failure is
caused by the projector which
is too cold. The DMD's should
not be operated at a
temperature lower then 10°C
(50°F). The projector has
some protections for that.
Below that temperature, the
engine is switched of, and the
result is a TI system status
failure.
This situation can occurs when
the projector is recently
installed and did not had the
time to acclimate to the normal
room temperature. There is
also a message that the
temperatures are too low. See
log files.
Make sure that the ambient temperature is within specs. Let the projector
acclimate to the normal room temperature which should be higher then 10°
C (50°F) and lower then 35°C (95°F). Do not ignite the lamp, otherwise
there is a risk for condensation.
Code 5801:
“
TI-link-decryptor - service door tamper event
”
Situation
Solution
The top cover plate and or the
side cover plate of the Light
Processor compartment has
been removed.
Clear the security warning. See service manual chapter
clear security warning on the projector
Brief procedure to clear the security warning:
1.
Ensure the top cover plate of the Light Processor compartment is
properly installed.
2.
Ensure the side cover plate of the Light Processor compartment is
properly installed.
3.
Ensure that all modules are properly installed into the Card Cage.
4.
Start up the projector.
5.
Initiate authorization by pushing the Key button on the Local Keypad.
6.
Enter the pin code within 5 seconds.
Defect security switches.
Replace DCI security switches of the Light Processor compartment
(reference 1 Image 25-63 & 2 Image 25-64)
Malfunction Signal Backplane
If switch replacement cures nothing then replace Signal Backplane. See
service manual chapter
“
”
1
Image 25-63
2
Image 25-64
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...