background image

1. Safety & Environmental Information

Label image

Label description

Label location

警告! 勿

看光束 眼睛勿直接接触可允

暴露的光束

(RG3 IEC EN 62471-5:2015 CLASS 1

IEC EN 60825-1:2014)

危害距离:

参考 安全手册

DANGER ! NE PAS REGARDER LE FAISCEAU EVITER TOUTE EXPOSITION DIRECTE
DES YEUX AU FAISCEAU. RG3 IEC EN 62471-5:2015. CLASS 1 IEC EN 60825-1:2014.
DISTANCE DE SECURITE : CONSULTER LE MANUEL DE SECURITE.

1.4

High Brightness precautions: Hazard Distance (HD)

HD

Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface
unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to
be) unsafe for exposure if the distance from a person to the light source is less than the HD.

Restriction Zone (RZ) based on the HD

The HD depends on the amount of lumens produced by the projector and the type of lens installed. See next chapter"HD in function
of modifying optics", page 8 
.

To protect untrained end users (as cinema visitors) the installation shall comply with the following installation requirements: Opera-
tors shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators’ eyes
from being in the hazard distance. Radiation levels in excess of the limits will not be permitted at any point less than 2.0 meter (SH)
above any surface upon which persons other than operators, performers, or employees are permitted to stand or less than 1.0 meter
(SH) lateral separation from any place where such persons are permitted to be. In non-cinema environments where unrestrained
behavior is reasonably foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential
exposure, for example by an individual sitting on another individual’s shoulders, within the HD.

These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section 6.6.5.

The end user must understand the risk and apply protective measures based upon the hazard distance as indicated on the label and
in the user information. Installation method, barriers, detection system or other applicable control measure shall prevent hazardous
eye access to the radiation within the hazard distance.

For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present
should be positioned in accordance with “the

fi

xed projector installation” parameters, resulting in a HD that does not extend into

the audience area unless the beam is at least 2.0 meter above the

fl

oor level. In non-cinema environments where unrestrained

behavior is reasonably foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential
exposure, for example by an individual sitting on another individual’s shoulders, within the HD. For example, a suf

fi

ciently large

separation height may be achieved by mounting the image projector on the ceiling or through the use of physical barriers.

For applications installed in the USA market the above limits do not apply. The relevant minimum separation height is 2.5 meter (8.2
ft) and the separation width is de

fi

ned as 1.0 meter (3.3 ft) by the FDA CDRH.

RA

TH

PR

RZ

HD

SW

1m

SW

SW

SW

HD

SH

RA

TH

RZ

SH

(B) TOP VIEW

(A) SIDE VIEW

Image 1-1
A

Side view.

B

Top view.

RA Restricted Access location (boot area of projector).
PR Projector.
TH Theater.
RZ Restriction Zone in the theater.
SH Separation Height.
SW Separation Width.

6

R5906846 DP2K-SLP SERIES 11/05/2017

Summary of Contents for DP2K SLP Series

Page 1: ...DP2K SLP Series Safety Environmental Information R5906846 00 11 05 2017 ...

Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco com en support Visit us at the web www barco com Printed in Belgium ...

Page 3: ...al installation codes should be adhered to Notice on safety This equipment is built in accordance with the requirements of the international safety standards IEC60950 1 EN60950 1 UL60950 1 and CAN CSA C22 2 No 60950 1 which are the safety standards of information technology equipment including electrical business equipment These safety standards impose important requirements on the use of safety c...

Page 4: ...her persons The term USER and OPERATOR refers to any person other than SERVICE PERSONNEL or TRAINED PROJECTIONISTS AUTHORIZED to operate professional projection systems The TRAINED PROJECTIONISTS may only perform the maintenance task described in the User Installation manual All other maintenance tasks and service tasks must be performed by qualified SERVICE PERSONNEL The DLP Cinema Systems are in...

Page 5: ...ss projector This projector embeds extremely high brightness radiance lasers this laser light is processed through the projectors optical path Native laser light is not accessible by the end user in any use case The light exiting the projection lens has been defused within the optical path representing a larger source and lower radiance value than native laser light Nevertheless the projected ligh...

Page 6: ...ating may lead to the projector shutting down during operation The projector must always be installed in a manner which ensures free flow of air into its air inlets If more than one projector is installed in a common projection booth the exhaust air flow requirements are valid for EACH individual projector system Note that inadequate air extraction or cooling will result in decreased life expectan...

Page 7: ...dropped or the cabinet has been damaged If the product exhibits a distinct change in performance indicating a need for service Replacement parts When replacement parts are required be sure the service technician has used original Barco replacement parts or authorized replacement parts which have the same characteristics as the Barco original part Unauthorized substitu tions may result in degraded ...

Page 8: ... height should be greater than or equal to 3 0 meter to prevent potential exposure for example by an individual sitting on another individual s shoulders within the HD These values are minimum values and are based on the guidance provided in IEC 62471 5 2015 section 6 6 5 The end user must understand the risk and apply protective measures based upon the hazard distance as indicated on the label an...

Page 9: ...tricted area sticker can be replaced by a sticker with only the symbol PR RESTRICTED AREA RESTRICTED AREA Image 1 2 1 5 HD for fully enclosed projection systems HD Hazard Distance HD is the distance measured from the projection lens at which the intensity or the energy per surface unit becomes lower than the applicable exposure limit on the cornea or on the skin The light beam is considered to be ...

Page 10: ... The restricted zone of the projected beam toward the screen taking into account 1 meter Separation Width SW from the beam onward Combined with the restricted zone related to the rear reflection from the screen HDreflection also taking into account a 1 meter lateral separation The HDreflection distance equals 25 of the difference between the determined HD distance and the projection distance to th...

Page 11: ...or details please visit the Barco website at http www barco com en AboutBarco weee Disposal of batteries in the product This product contains batteries covered by the Directive 2006 66 EC which must be collected and disposed of separately from municipal waste If the battery contains more than the specified values of lead Pb mercury Hg or cadmium Cd these chemical symbols will appear below the cros...

Page 12: ...District 102200 Beijing P R C 北京市昌平区中关村科技园区昌平园昌盛路16号 邮政编码 102200 1 11 Download Product Manual Download Product Manual Product manuals and documentation are available online at www barco com td Registration may be required follow the instructions given on the website IMPORTANT Read Installation Instructions before connecting equipment to the mains power supply 10 R5906846 DP2K SLP SERIES 11 05 2017...

Reviews: