1. Safety

RA

TH

PR

RZ

HD

SW

1m

SW

SW

SW

HD

SH

RA

TH

RZ

SH

(B) TOP VIEW

(A) SIDE VIEW

Image 1-1
A

Side view.

B

Top view.

RA Restricted Access location (booth area of projector).
PR Projector.
TH Theater.
RZ Restriction Zone in the theater.
SH Separation Height. Must be minimum 2 meter.
SW Separation Width. Must be minimum 1 meter.

Based on national requirements, no person is allowed to enter the projected beam within the zone between the projection lens and
the related hazard distance (HD). This shall be physically impossible by creating suf

fi

cient separation height or by placing barriers.

The minimum separation height takes into account the surface upon which persons are assumed to stand.

On image 1-1 a typical setup is displayed. It must be veri

fi

ed by the installer if these minimum requirements are met. If required a

restricted zone (RZ) in the theater must be established. This can be done by using physical barrier, like a red rope as illustrated in
image 1-2.

PR

Image 1-2

1.5

HD in function of the lens Throw Ratio (TR)

TR (Throw Ratio)

The ratio of the distance to the screen (throw) to the screen width.

6

R5906695 DP2K-E SERIES 19/06/2015

Summary of Contents for DP2K-E series

Page 1: ...DP2K E series Safety manual R5906695 00 19 06 2015...

Page 2: ...x 86 10 8970 2793 Support www barco com en support Visit us at the web www barco com Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco...

Page 3: ...standards IEC60950 1 EN60950 1 UL60950 1 and CAN CSA C22 2 No 60950 1 which are the safety standards of information technology equipment including electrical business equipment These safety standards...

Page 4: ...ified service personnel before resuming operations Do not disassemble this projector always take it to a trained service person when service or repair work is required Do not use an accessory attachme...

Page 5: ...e materials away from the projector at all times Mount the projector in a well ventilated area away from sources of ignition and out of direct sun light Never expose the projector to rain or moisture...

Page 6: ...or to change other control settings not specially discussed in this manual can lead to permanent damage to the projector and cancellation of the warranty Remove all power from the projector and refer...

Page 7: ...am can thus be considered as dangerous if the operator is closer from the source than the HD Restriction Zone RZ based on the HD The HD is defined from the projection lens surface towards the position...

Page 8: ...distance HD This shall be physically impossible by creating sufficient separation height or by placing barriers The minimum separation height takes into account the surface upon which persons are ass...

Page 9: ...ard Distance HD m TR 0 0 2 0 4 0 6 0 8 1 1 2 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 3 4 3 6 3 8 4 0 4 2 4 4 4 6 Image 1 3 HD in meter in function of the Throw Ratio TR R5906695 DP2K E SERIES...

Reviews: