![Barco DP2K-12C Service Manual Download Page 75](http://html1.mh-extra.com/html/barco/dp2k-12c/dp2k-12c_service-manual_4083615075.webp)
4. Troubleshooting
Code 6061: “+24v - voltage high” (Warning)
Situation
Solution
Malfunction Fan Control board or
SMPS board.
Measure on the Signal Backplane the +24V voltage on pin 9, 10, 11 or 12 of the
connector of the black wire unit which comes from the SMPS board. See image 4-43.
If the measured voltage is about 24V then replace the Fan Control board. See
"Removing a board in the card cage", page 213. Otherwise replace the SMPS board.
See"Replacement of the Switched Mode Power Supply", page 281.
12
24
+24V
11
23
10
22
9
21
8
20
+VTEC
GND
7
19
6
18
5
17
4
16
3
15
++12V
2
14
1
13
24
24
13
13
Image 4-43
Code 6062: “+24v - voltage too low” (Error)
This error code is probably preceded by the warning code 6063: “+24v - voltage low”. The same troubleshooting table can be
applied.
Code 6063: “+24v - voltage low” (Warning)
Situation
Solution
Malfunction Fan Control board or
SMPS board.
Measure on the Signal Backplane the +24V voltage on pin 9, 10, 11 or 12 of the
connector of the black wire unit which comes from the SMPS board. See image 4-43.
If the measured voltage is about 24V then replace the Fan Control board. See
"Removing a board in the card cage", page 213. Otherwise replace the SMPS board.
See"Replacement of the Switched Mode Power Supply", page 281.
Short circuit or bad connection.
1.
Check the Signal Backplane for bad connections. Ensure that all wire units are
well connected.
(Note that the +24V supply is generated on the SMPS board and enters the Fan
Control board and Cinema Control board via the Signal Backplane)
2.
Check the wiring of the Anode fan for short circuits.
3.
Check the wiring of the Cathode fan for short circuits.
Code 6071: “++12v - voltage high” (Warning)
Situation
Solution
Malfunction Fan Control board or
SMPS board.
Measure on the Signal Backplane the ++12V voltage on pin 1, 2 or 3 of the connector of
the black wire unit which comes from the SMPS board. See image 4-43.
If the measured voltage is about12V then replace the Fan Control board. See
"Removing a board in the card cage", page 213. Otherwise replace the SMPS board.
See"Replacement of the Switched Mode Power Supply", page 281.
R5905043 DP2K-12C/11CX 19/02/2018
71
Summary of Contents for DP2K-12C
Page 1: ...DP2K 12C 11CX Service manual R5905043 15 19 02 2018...
Page 4: ......
Page 8: ...Table of contents 4 R5905043 DP2K 12C 11CX 19 02 2018...
Page 12: ...1 Safety 8 R5905043 DP2K 12C 11CX 19 02 2018...
Page 31: ...4 Troubleshooting 4 TROUBLESHOOTING R5905043 DP2K 12C 11CX 19 02 2018 27...
Page 32: ...4 Troubleshooting 28 R5905043 DP2K 12C 11CX 19 02 2018...
Page 96: ...5 Removal and installation of projector covers 92 R5905043 DP2K 12C 11CX 19 02 2018...
Page 121: ...6 Lamps and lamp houses Image 6 38 R5905043 DP2K 12C 11CX 19 02 2018 117...
Page 138: ...7 Cold mirror assembly 134 R5905043 DP2K 12C 11CX 19 02 2018...
Page 222: ...12 Card Cage 1 Image 12 11 218 R5905043 DP2K 12C 11CX 19 02 2018...
Page 225: ...12 Card Cage Image 12 15 Button unit removal R5905043 DP2K 12C 11CX 19 02 2018 221...
Page 281: ...15 Power input Image 15 13 Mains AC compartment cover R5905043 DP2K 12C 11CX 19 02 2018 277...
Page 282: ...15 Power input 278 R5905043 DP2K 12C 11CX 19 02 2018...
Page 306: ...18 Lamp power supply single module 302 R5905043 DP2K 12C 11CX 19 02 2018...
Page 340: ...21 Maintenance procedures 336 R5905043 DP2K 12C 11CX 19 02 2018...
Page 350: ...A Pin configurations 346 R5905043 DP2K 12C 11CX 19 02 2018...
Page 351: ...B Input formats B INPUT FORMATS R5905043 DP2K 12C 11CX 19 02 2018 347...