2.1 Installation requirements
Environmental conditions
The table below summarizes the physical environment in which the DPxK-32B series projector may be safely
operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10 °C (50 °F) to 35 °C (95 °F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean office environment (equivalent with
cleanroom standard ISO 14644-1 ISO Class
9)
n.a.
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the
Light Processor Unit.
Cooling requirements
The projector is fan cooled and must be installed with sufficient space around the projector head, minimum 20
cm (8 inch) to ensure sufficient air flow. It should be used in an area where the ambient temperature, as
measured at the projector air inlet , does not 35°C (+95°F).
The installation of an
exhaust system
is
MANDATORY
. The installed exhaust blower must remove an air
volume of minimum
10m
3
/min (350 CFM)
measured at the exhaust output of the projector.
Main Power requirements
The DPxK-32B operates from a nominal 230/400V 3W+N+PE 16A 50-60Hz (Y connection) or 208V 3W+PE
27A 50-60Hz (Δ connection). The projector must be switched internally between a star connection to a delta
connection or vice versa. See
Power input setup of the DPxK-32B
”
, page 29.
For a 3W+N+PE system, 400V is measured between the lines, 230V is measured between the lines and the
neutral.
For a 3W+PE system, 208V is measured between the lines.
The power cord required to connect the projector with the power net is not delivered with the projector. It is the
responsibility of the customer to provide the correct type of power cord.
The cross-sectional area of the conductors in the power supply cord shall not be less than 4 mm
2
or AWG 10.
The power cord must be rated for minimum 300V in case of a 3W+PE (208V) power system, and minimum
500V in case of a 3W+N+PE (230/400V) power system.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that
the instrument panel and cabinet be grounded. In no event shall this projector be operated without an
adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes
and conduit types must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the
power to the equipment mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
WARNING:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet
for removal of all power from the unit
Summary of Contents for DP K-32B Series
Page 1: ...ENABLING BRIGHT OUTCOMES User and Installation manual For DP2K 32B and DP4K 32B DPxK 32B ...
Page 8: ...R5905754 13 DPxK 32B 8 ...
Page 58: ...R5905754 13 DPxK 32B 58 Lamp Lamp House ...
Page 76: ...R5905754 13 DPxK 32B 76 Lenses lens holder ...
Page 94: ...R5905754 13 DPxK 32B 94 Input communication ...
Page 96: ...R5905754 13 DPxK 32B 96 Installing a HDD into the ICMP ICMP ...
Page 128: ...R5905754 13 DPxK 32B 128 Communicator Touch Panel ...
Page 154: ...R5905754 13 DPxK 32B 154 Maintenance ...
Page 162: ...R5905754 13 DPxK 32B 162 Convergence ...
Page 170: ...R5905754 13 DPxK 32B 170 Specifications ...
Page 188: ...Index R5905754 13 DPxK 32B 188 USB 3 0 101 User definition 10 Z Zoom 65 ...
Page 189: ...R5905754 13 DPxK 32B 189 ...
Page 190: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5905754 13 2018 11 12 ...