8.2 Lamp replacement
(UHP units only)
The LAMP indicators on the keypad will turn red when lamp life expires or if the lamp fails.
Change the lamp when lifetime expires. Always replace lamp with the same type and rating.
USE ORIGINAL LAMPS ONLY.
The lamp includes an electronic lamp timer that is tracking the life time of the lamp.
Allow lamp to cool down before changing. One lamp may be changed while the other lamp is
operating (hot-swap).
Release the screw (LAMP 1) or (LAMP 2) depending on which lamp that needs to be re-
placed.
Be careful not to touch the protective glass when replacing the lamp,
this may cause the protective glass to overheat and break while in use.
Be extremely careful when removing the lamp module. In the unlikely
event that the bulb ruptures, small glass fragments may be generated.
The lamp module is designed to contain these fragments, but use
caution when removing the lamp module.
A
Open the lamp lid(s).
B
Turn the three locking screws a quarter turn anti-clockwise.
C
Pull the lamp out.
D
Replace with a new lamp in reverse order.
E
Insert a new lamp. Observe the guide pins.
F
Turn the tree locking screws a quarter turn clockwise.
G
Close the lamp lid.
H
Turn the locking screw clockwise.
In the unlikely event of a lamp rapture, a limited amount of mercury vapor
may be emitted into the room. To avoid inhailing this mercury vapor
(which is toxic, and can be harmful for lungs and nervous system) the
room should be thoroughly ventilated for a period of at least 30 minutes.
There are no known health hazards from exposure to lamps that are
intact and which are used within an enclosed fixture. No adverse effects
are expected from occational exposure to broken lamps. As a matter of
good practise, avoid prolonged or frequent exposure to lamps unless
there is adequate ventilation. The major hazard from broken lamps is the
possibility of sustaining glass cuts.
A
B
H
G
F
E
D
C
Summary of Contents for CRPN-52B
Page 2: ...User Manual Introduction english 2 ...
Page 8: ...CR series User Manual Introduction english 8 ...
Page 14: ...CR series User Manual What s in the box english 14 ...
Page 20: ...CR series User Manual Getting to know the projector english 20 ...
Page 44: ...CR series User Manual Technical specifications english 44 ...
Page 46: ...CR series CR series 简介 简体中文 2 ...
Page 50: ...CR Series 用户手册 简介 简体中文 6 ...
Page 58: ...简体中文 14 CR Series 用户手册 包装清单 ...
Page 64: ...简体中文 20 CR Series 用户手册 了解投影机 ...
Page 82: ...简体中文 38 CR Series 用户手册 优化图片 图 7 4 视频 2 伽玛 图 7 5 计算机 1 伽玛 图 7 6 计算机 2 伽玛 ...
Page 88: ...简体中文 44 CR Series 用户手册 技术规范 ...