11
Leak Check
WARNING!!!
Do not use an open flame to check for leaks.
Do not smoke during testing.
Do not test indoors.
A leak check must be performed whenever the gas cylinder is replaced.
NOTE
1. Make sure the gas control knob (I2) is on the “
OFF
" position. Open access doors.
2. Make sure the gas cylinder is correctly and securely connected to the pressure regulator,
with a tight fit.
3. Turn on the gas cylinder valve (1). Apply 50% soap and 50% water solution to the gas hose
at connections between the knob (L2) and the gas cylinder.
4. If there is a leak, you will see bubbles form. In the case of a leak, turn off the gas supply,
unscrew the connections. Reconnect the gas hose and retest. If the leak persists, consult
the customer service center for assistance.
5. If the connection is sound, continue to the next step.
Fig.7
Fig.8
Fig.9
K2
L2
F
B2