19
UNIVERSAL-6 85
Installation instructions
2.3 ACCESSORIES
The following accessories can be supplied by your dealer:
Part. no
Accessorie
338223
Convection set General: (for convection air extraction)
Advice:
• Appliance without convection fan:
The use of a convection set is strongly recommended.
• Appliance with convection fan:
The use of a convection set is possible, but not mandatory.
302188
• 1x Flexible aluminium pipe Ø125 mm, L= 3 m (max.)
310178
• 2x Fitting box 135x135 mm
309872
• 2x Convection exit grid, white, 145 x 145 mm
309730
• 2x Collar adaptor Ø125 mm
304040
• 4x Hose clamp Ø125 mm
339426
Built-in frame
339425
Deepened frame
339423
Classic frame
309872
Grate ventilation chimney
310178
Fitting box for grate ventilation chimney
339377
Set of high adjustable feet
339261
2x Cover plate
2.4 HEARTH REQUIREMENTS
The appliance must be placed on a constructional hearth made of solid non-combustible
material, such as concrete or masonry, at least 125 mm thick, including the thickness of
any non-combustible fl oor and/or decorative surface. Combustible material should not
be placed beneath the constructional hearths unless there is an air-space of at least
50 mm between the underside of the hearth and the combustible material, or the
combustible material is at least 250 mm below the top of the hearth.