Caution:
• During operation of the appliance the outer side of the flue system
becomes hot. Refer to the installation instructions of the flue system for
safe installation. Follow these instructions with regard to safe distances to
combustible material.
If the appliance is installed on an unlined, masonry flue with a large diameter, consider
using a flue lining system to improve the performance of the appliance.
1. Connect the flue to the flue gas connection on the appliance. If necessary use a steel
flue adaptor.
2. If a flexible stainless steel flue is used, secure the flue connection with 2 clamps.
3. If the flue is connected to an existing (masonry) chimney, make sure to use a
chimney adapter with the correct dimensions
4. Make sure that all mechanical connections of the flue system are correctly used.
5. Make sure that all of the flue system is gas-tight,
6. Insulate any non-insulated pipes with ceramic insulation wool. Refer to
for the
material requirements.
6.3.5
Connect the convection set (optional)
Note: If the Unilux-7 75 has a 45 degree flue connector, the optional
convection set is not available for this appliance.
1. Remove the break out plates in the convection air outlet openings with a hammer.
2. Put the collar adaptors in the open convection air outlet openings.
3. Bend out the 3 lips on each collar adaptor, to attach the collar adaptor on the outlet
opening.
Installation
Unilux-7 75
29
Summary of Contents for Unilux-7 45
Page 1: ...Installation and maintenance manual Unilux 7 75 Serial number Production date...
Page 40: ...Figure 15 Dimensions of frameless appliance with steel frame door Dimensions 40 Unilux 7 75...
Page 49: ...Warranty Terms Unilux 7 75 49...
Page 50: ...Warranty Terms 50 Unilux 7 75...
Page 51: ...Warranty Terms Unilux 7 75 51...