Technical data

Name

Barbas

Model

Unilux-7 40

Tested in accordance with

EN 13229:2001-A2:2004
EN 16510-1 annex D, E, F

Energy efficiency index (according EU

2015/1186)

100

Energy efficiency class

A

Fuel

• Wood logs
• Wood briquettes (without binder)

Nominal fuel load

1.3 kg

Nominal heat output (net)

5 kW

Minimum heat output (net)

4 kW

Useful efficiency (Net Calorific Value (NCV)) at

nominal heat output

76 %

Useful efficiency (Net Calorific Value (NCV)) at

minimum heat output (indicative)

81 %

Indirect heating function

No

Room sealed

No

The specific precautions that shall be taken

when the local space heater is assembled, in-

stalled or maintained, are listed in the attached

documents:

• Installation and maintenance manual
• User manual

Technical data

22

Unilux-7 40

Summary of Contents for Unilux-7 40

Page 1: ...User manual Unilux 7 40 Serial number Production date...

Page 2: ...ise without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this documen...

Page 3: ...th regard to the environment 10 5 Fuel 11 5 1 Fuel types 11 5 2 Fuel amount 11 6 Operation 12 6 1 Preparation before first use 12 6 2 First use of the appliance 13 6 3 Firing the appliance 13 6 3 1 Fi...

Page 4: ...tion Bladel February 1 2021 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in point 7 This declaration of perform...

Page 5: ...ent show a typical setup The illustrations are for instructional use only 2 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety c...

Page 6: ...th a steel frame door A Door handle B Glass C Primary air inlet D Grate F Log guard G Ash tray under the grate H Ceramic panels I Top flue connector1 J Control lever Figure 1 Top view of the Unilux 7...

Page 7: ...teel P Lower baffle ceramic Q Connection for external combustion air Figure 2 Bottom view of the Unilux 7 40 with screened door R Connection for external combustion air S Rear flue connector Figure 3...

Page 8: ...fuels The appliance is intended for use with the door closed The appliance may only be used at the location that meets the requirements for the installation of the appliance The appliance is intended...

Page 9: ...Wear the glove and use the operating hook or a poke when refilling the appliance Make sure that your clothing does not touch the appliance Especially synthetic clothing ignites easy and burns intense...

Page 10: ...nmentally friendly way Dispose of ceramic heat resistant glass as household waste Do not dispose of ceramic heat resistant glass in a glass recycling container Dispose of an obsolete appliance accordi...

Page 11: ...shly chopped wood Coal anthracite and other bituminous fuels Lignite peat Using unsuitable fuels cause excess smoke black glass combustible deposits in the chimney and can damage the appliance 5 2 Fue...

Page 12: ...etely by moving the door handle Steel frame door Turn the handle forward to open the door and downward to close the door Screened glass door Turn the handle forward to open the door and backward to cl...

Page 13: ...3 1 First load and ignition At the beginning the appliance and chimney are cold It is important that both the appliance and chimney reach a temperature that guarantees a good functioning of the appli...

Page 14: ...ht the firestarter cubes with a lighter or a match 9 Close the door of the appliance After approximately 20 minutes the wood logs burn Dependent on the quality of the chimney the wood logs burn for ap...

Page 15: ...cription The best reloading moment is dependent on the flue draught A high flue draught requires reloading when the flames have completely disappeared If the flue draught is low reloading must be done...

Page 16: ...d airwash inlet is closed Warning Setting the control lever in the far left position all air inlets closed when the fuel is burning leads to excessive emission of hazardous gasses example carbon monox...

Page 17: ...nt flow of the flue gas in the chimney Do the next steps to decrease the flow resistance 1 Loosen the nut above the heat shield with a 3 mm hexagonal key and a 10 mm fork spanner Unscrew the socket sc...

Page 18: ...1 for advice on the required fuel quality Make sure the door of the appliance is closed when in use Only open the door for ignition and to refuel Do not remove all the ashes An ash layer in the combus...

Page 19: ...ere are no glowing embers 2 Remove the ashes with a small scoop 3 Lift the grate with the operating hook and remove the grate 4 Remove the ashtray and empty it 5 Make sure there are no ashes in the sp...

Page 20: ...the recommended ignition procedure Refer to chapter 6 3 1 Use the recommended amount of fuel Refer to chapter 5 2 The wood logs burn too fast Primary air inlet is open Close the primary air supply Ad...

Page 21: ...e wood logs is too high Use dried wood logs with a moisture content of 10 20 Use wood briquettes The seal around the door is damaged Contact your dealer Some cold air flows out from the front of the a...

Page 22: ...nal heat output net 5 kW Minimum heat output net 4 kW Useful efficiency Net Calorific Value NCV at nominal heat output 76 Useful efficiency Net Calorific Value NCV at minimum heat output indicative 81...

Page 23: ...after they have manifested themselves 3 Complaints will only be accepted if they are reported to the Barbas dealer together with the serial number of the Barbas appliance which is stated on the front...

Page 24: ...oes not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warranty cond...

Page 25: ...Warranty Terms Unilux 7 40 25...

Page 26: ...Warranty Terms 26 Unilux 7 40...

Page 27: ...Warranty Terms Unilux 7 40 27...

Page 28: ...Your Barbas dealer 001 25 03 2021 351074...

Reviews: