GENERAL HEATING TIPS

• 

Burn dry wood only. Damp wood not only burns poorly, it causes more pollution 
in the appliance (window), the chimney, your room (when opening the door of the 
appliance, for instance) and the environment. W

ood can only be classifi ed as dry if it 

has been stored under a Dutch barn for at least two years (not covered with plastic). 
Never use painted or impregnated wood. The gases emitted when burning painted or 
impregnated wood are aggressive and will affect the appliance, the environment and 
your health. 

•  Ensure that your appliance burns well. The smoke generated should be translucent 

or white and the windows of the appliance will remain clean. We recommend that 
you do not ‘pinch off’ your appliance (by closing all air openings). Doing so will hinder 
combustion which, apart from polluting the atmosphere, will lead to deposits of soot 
and tar in your chimney (which, unchecked, will increase the risk of chimney fi re).

•  Keep the door shut when the appliance is burning. Doing so improves the 

performance of your appliance 8 - 10 times, benefi ting the environment and the heat 
in your home (less topping up). You will also prevent appliance damage from any 
particles the appliance ‘spits’ out (this is a particular problem with softwood from 
conifers). If your fl oor contains fl ammable material, an extra fl oor plate is required.

  The appliance must not be operated with the air control or door left open except as 

directed in this operating manual. Operation with the air control open or door left 
open can cause excess smoke.

•  Avoid lighting an appliance in misty or still conditions. If the wind is still, there is 

hardly any draught in the cold chimney. As smoke is heavier than air, there is a 
chance that smoke will enter the room. If there is mist in the air, smoke coming out of 
your chimney will cool quickly and fall, causing problems in your area.

•  Do not extinguish your appliance with water - let it burn out. The part of the inner 

lining that is in direct contact with the appliance is clad with fi re-resistant material. 
Sudden changes in temperature may lead to it deforming or cracks appearing.

•  Chimney fi re.
  If, despite all the precautions, a fi re should occur in the chimney (you generally notice 

that because of a roaring sound in the chimney), do the following:

  •  Immediately shut the chimney fl ap (if fi tted).
  •  Immediately shut the air supply to the appliance.
  •  Call the fi re brigade (

(

 112).

  •  Quickly quench the fi re in the appliance with sand or soda in order to  prevent  
    smoke in your house.
  •  Never use water to put out the fi re.
  •  Ventilate.
  •  If there has been a fi re in the chimney, have it swept and inspected for damage  
    and leakage.

Summary of Contents for UNILUX-6 75

Page 1: ...pliance Serial number Production date Barbas wishes you many cosy evenings with your new appliance This document is an essential part of your appliance Read it carefully before use of the appliance an...

Page 2: ......

Page 3: ...Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in p...

Page 4: ...4 UNILUX 6 75 Instructions for use...

Page 5: ...ions for use CONTENTS Page 1 INTRODUCTION 7 2 SAFETY 8 3 OPERATION 10 4 USING THE APPLIANCE FOR THE FIRST TIME 11 5 USE 14 6 FUEL 21 7 MAINTENANCE 23 8 FREQUENTLY ASKED QUESTIONS 25 9 TECHNICAL DATA 2...

Page 6: ...6 UNILUX 6 75 Instructions for use...

Page 7: ...smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any xed boiler if located in a designated smoke control area It is also an offence to acquire an...

Page 8: ...rous It is not allowed to connect the appliance to a ue which is already connected to another appliance Make sure you know what state your chimney is in Cracks in the chimney may not only lead to damp...

Page 9: ...appliance to burn rubbish Do not use your appliance as a barbecue This can cause ammable fat deposits to be left in the chimney and hastens the chimney becoming clogged Ensure at all times that child...

Page 10: ...nvection set chimney breast convection air 6 Grate 7 Ashtray 8 Inlet opening 2x grate chimney breast ventilation air chimney breast 9 Combustion air supply slider Combined operation for the primary se...

Page 11: ...ated with a lacquer layer resistant to high temperature During the rst hours of operation the burning in of the lacquer may result in an unplea sant smell This is harmless however To speed up the proc...

Page 12: ...eck all available functions before using the appliance for the rst time Check the opening and closing operation of the door Turn the handle all the way down Door is locked Handle forwards The door rel...

Page 13: ...s Check the operation of the slider for the regulation of the combustion air intake middle below the window Check whether the ashtray is completely empty Report any defects immediately to your dealer...

Page 14: ...tart the appliance the chimney is still cold and there is little draught Before the re is lit turn the operating handle completely to the right maximum air supply Open any chimney valve and the valve...

Page 15: ...you can adjust the air supply for further combustion Make sure the appliance burns quietly Note Once you have got the appliance going leave the air supply slider in the centre position for optimal co...

Page 16: ...there is insuf cient burning material in the rebed to light a new fuel charge excessive smoke emision can occur Refuelling must be carried out onto a suf cient quantity of glowing embers and ash that...

Page 17: ...ls 5 5 CLEANING THE WINDOW After several burning hours a light deposit may form on the inner side of the window Once the appliance has cooled down this deposit can be removed using glass cleaner or ce...

Page 18: ...le if the appliance is equipped with a 45 degrees chimney connection If there is too much ow resistance in the chimney causing insuf cent ow of of the ue gasses one can increase the chimney draught To...

Page 19: ...nce spits out this is a particular problem with softwood from conifers If your oor contains ammable material an extra oor plate is required The appliance must not be operated with the air control or d...

Page 20: ...ractor When the door is open the chimney draws in much more air than is necessary for combustion This relatively cool air cools down the appliance Excessive chimney draught The combustion air does not...

Page 21: ...r appliance and the environment Paraf n containing open appliance lighters are not suitable for a closed appliance A closed appliance generates more heat than an open appliance thus the paraf n will m...

Page 22: ...e 5 0 The heating value of wood 18 7 MJ kg at 0 humidity is not affected by the sort of wood What does make a difference is the relative humidity of the wood 15 6 MJ kg at 15 humidity Per lling for 45...

Page 23: ...the appliance again Broken ceramic heat resistant glass may not be thrown away in a glass container but must be included in normal household waste Cleaning the appliance Wait for the appliance to cool...

Page 24: ...appliance are not permitted House Ensure that as little dust and as few particles of cigarette smoke candles and oil lamps as possible pollute the air in the room in which the appliance is used Heatin...

Page 25: ...lean wood in the appliance Wood that is too damp immediately gives off lots of ash Make sure the seals are in good working order Any air seeping out around the glass part of the door will cool the air...

Page 26: ...tent of 10 The wood burns up too quickly What should I do Ensure that air cannot get in underneath the fuel Move the combustion air supply slider towards the position The primary air supply is now clo...

Page 27: ...s The combustion of wood involves the following steps Drying The rst step is that the fuel wood dries out Even at low temperatures 100 C any moisture still in the wood will evaporate This drying proce...

Page 28: ...r Flue gas connection 146 mm 150 mm ext Weight 107 kg Inside Interior side panels Heat resistant panels 1400 kg m3 1300 C Interior bottom Steel heat resistant and rust proof Inner lining Steel heat re...

Page 29: ...himney connection Combustion air supply At least 50 cm2 opening in the room where the re is located or a outside air supply opening of 80 mm in wall oor Options Convection set Clean Air Act exemption...

Page 30: ...s based on the applicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Barbas dealer 2 2 Complaints should be reported as quickly...

Page 31: ...parts such as glass glass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Barbas Bell...

Page 32: ...05 200519 340718 Your Barbas dealer...

Reviews: