14
UNILUX-3 200 L / 200 R / 300
3.3. FITTING
A fi replace insert can be fi tted in the newly-built or existing chimney breast
of an open fi re. When fi tting, both fi re safety and operational safety must be
safeguarded. The fi tter is responsible for this.
General guidelines:
• If there is a wooden beam above the fi tting location, heat must not radiate
directly onto it. An insulation plate must be hung below the beam, leaving an
air gap between it and the beam of at least 1 cm.
• Always use (white) unbound ceramic insulation wool. Bound material
(yellow), such as glass and rock wool, spreads an irritating smell on heating,
causes excess smoke and is unsuitable for high temperatures (insulation
requirements: temperature
≥
700°C, density 80 kg/m
3
).
• Before fi tting, remove the door to protect the glass.