1
Non-flammable spacer
2
Non-flammable insulation plate
3
Flammable wall
Figure 11. Clearances to flammable wall - Top view
Table 4: dimensions and minimum clearances to a flammable wall
Description
Insulation plate 25
mm
Insulation plate 35
mm
A
Air gap
25 mm
25 mm
B
Thickness plate
25 mm
35 mm
C
Air gap / Spacer
25 mm
15 mm
D
A+B+C
75 mm
75 mm
E
B+C
50 mm
50 mm
F
Minimum 3 mm clearance between appliance and surrounding construction
4.3
Clearance to flammable floor (under the appliance)
Put a non-flammable insulation plate with a minimum thickness of 25 mm under the
appliance. To avoid damage to this non-flammable plate, put ceramic or steel tiles
(approx. 10 x 10 cm) under the feet of the appliance.
Put a non-flammable floor stone (hearth plate) if the underside of the appliance is less
than 10 cm above a flammable floor.
4.4
Clearances to flammable ceiling
Put a non-flammable insulation plate (false ceiling) of minimum 2.5 cm thickness at a
height of minimum 50 cm above the appliance. Keep a free space of minimum 10 cm
between the insulation plate and the flammable ceiling.
Clearances
Gas Fire Front 70-60
23
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...