background image

IItem

Description

C

Chimney

The chimney extracts the flue gases from the appliance.

D

Ventilation air outlet The heated air in the chimney breast is extracted by the outlet open-

ings into the room. This prevents overheating of the chimney breast.

E

Insulating material

The appliance insulation to keep the heat inside the appliance

F

Air supply

Provides the room with air for the appliance.

G

Adjustable feet

4 adjustable feet to level the appliance.

Installation with external combustion air supply, with convection package and convection

ventilator

Item

Description

A

Combustion air inlet Provides the appliance with external combustion air. A flexible alumi-

num pipe is connected between the combustion air inlet box and the

outer side of the house.

B

Convection air inlet

opening

Provides air for the convection ventilator. A flexible aluminum pipe is

connected between the convection air inlet opening and the convec-

tion air box.

C

Ventilation air inlet

opening

Inlet opening for air for ventilation of the chimney breast.

D

Chimney

The chimney extracts the flue gases from the appliance.

E

Insulating material

The appliance insulation to keep the heat inside the appliance.

F

Convection air out-

let

The heated air is extracted through flexible aluminum pipes by the out-

let grate into the room.

G

Ventilation air outlet The heated air in the chimney breast is extracted by the outlet grate in-

to the room. This prevents overheating of the chimney breast.

H

High adjustable feet

(option)

Set of 2 adjustable frames with 2 adjustable feet each to put the appli-

ance on a higher position.

Description

Falcon 66/56

13

Summary of Contents for Falcon 66/56

Page 1: ...I Installation and maintenance manual Falcon 66 56 Serial number Production date 9HUVLRQ QXPEHU 116 DWH 21 8 8...

Page 2: ...se without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document...

Page 3: ...quirements 16 6 1 1 General requirements 16 6 1 2 Requirements on the installation of the appliance 16 6 1 3 Requirements on the chimney 17 6 2 Preparation for installation 17 6 3 Installation procedu...

Page 4: ...chnical data 29 9 Dimensions 31 9 1 Frameless appliance 31 9 2 Appliance with built in frame 32 9 3 Appliance with 3 sided classic frame 33 9 4 Appliance with 4 sided classic frame 34 10 Warranty Term...

Page 5: ...d function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in point 7 This declaration of...

Page 6: ...England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Ac...

Page 7: ...w a typical setup The illustrations are for instructional use only 3 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter...

Page 8: ...t the ashes that fall through the grate F Cast iron panels Cover of the rear and sides of the combustion chamber G Heat shield Protects the steel in the top of the appliance against excessive heat rad...

Page 9: ...pports the lower baffle L Secondary air inlet Combustion air supply through the back wall into the combustion chamber Secondary air is used for clean burning M Air wash inlet Combustion air supply thr...

Page 10: ...convection air through the convection system Q Convection ventila tor Combustion air inlet box option Cover for the convection ventilator with inlet openings for the com bustion air S Adjustable feet...

Page 11: ...nded for indoor use to heat the room wherein it is installed Do not use it for other purposes The appliance is intended for use with wood logs or wood briquettes as fuel Do not use other fuels The app...

Page 12: ...installation room or from external N Note The appliance is a room sealed appliance when combustion air comes from the outer side of the building through a flexible pipe that is connected to the combu...

Page 13: ...ir inlet box and the outer side of the house B Convection air inlet opening Provides air for the convection ventilator A flexible aluminum pipe is connected between the convection air inlet opening an...

Page 14: ...I Item Description I Flexible aluminum pipe convection set option Extracts the heated convection air from the appliance Description 14 Falcon 66 56...

Page 15: ...Manual Do not use masking tape on the appliance Masking tape can damage the finish of the appliance Do not use fiberglass rockwool or any other sort of insulation material These materials produce a pu...

Page 16: ...properly ventilated 6 1 2 Requirements on the installation of the appliance Do not install the appliance against a combustible rear wall or combustible side wall The appliance must be installed minimu...

Page 17: ...2 bends of 45 The chimney outlet must be at least 5 meter above the top of the appliance The chimney outlet must be at least 40 cm above the top of a sloped roof The chimney outlet must be at least 1...

Page 18: ...mes You can use the carrying tubes to move the appliance 2 Install the appliance Make sure the distance between the appliance and rear wall is approximately 10 cm minimum 3 Remove the carrying tubes a...

Page 19: ...prove the performance of the appliance 1 Connect the flue to the flue gas connection on the appliance If necessary use a steel flue adaptor 2 If a flexible stainless steel flue is used secure the flue...

Page 20: ...er vapor condensation in the appliance when not in use 1 Identify the location in the outer wall or in the floor to a ventilated crawl space for the external combustion air supply inlet 2 Make a hole...

Page 21: ...e inlet opening d Connect a flexible aluminum pipe B on the collar adaptor A Use a hose clamp 2 Connect the flexible aluminum pipe to a fitting box in the chimney breast 3 On the appliance remove the...

Page 22: ...iance Keep approximately 10 cm free between the front of the appliance and the front of the fireplace 6 3 7 Build the fireplace Caution If the appliance is placed against a load bearing wall or a comb...

Page 23: ...east 50 mm from a combustible ceiling Table 7 Installation against a combustible ceiling Item Description A Appliance B Ventilation air outlet Outlet of heated air from the chimney breast C Insulation...

Page 24: ...inlets b If applicable install the fitting boxes of the convection air inlets c If applicable install the dimmer of the convection ventilator 5 If applicable install a mantle iron to support the brick...

Page 25: ...upply is not blocked by leaves or other debris 2 Clean the inlet of the pipe of the external combustion air supply 7 3 Convection air system Note Do the procedure in this section only when a convectio...

Page 26: ...ttached to the socket screw 2 Push up 1 the front of the heat shield and pull it forward 2 and move downward to a vertical position 3 3 Remove the heat shield from the appliance 7 5 2 Remove the lower...

Page 27: ...upper baffle over the support 5 Lower the right side of the upper baffle and remove it from the appliance 7 6 Place the baffles Do all procedures of 7 5 in reverse order 1 Place the upper baffle Make...

Page 28: ...Annual maintenance 2 28 Falcon 66 56...

Page 29: ...eak rate at 10 Pa 1 0 m3 h at 273 K 1013 hPa Emissions at 13 O2 273 K 1013 hPa carbon monoxide CO 0 08 vol 1027 mg Nm3 particles PM 30 mg Nm3 organic gaseous compounds OGC 71 mg Nm3 nitrogen oxides NO...

Page 30: ...5 mm on the optional convection ventilator combus tion air inlet box O Options Convection ventilator combustion air inlet box Combustion air inlet box Set of 2 adjustable height frames Electrical ener...

Page 31: ...9 9 Dimensions 9 1 Frameless appliance Dimensions Falcon 66 56 31...

Page 32: ...9 9 2 Appliance with built in frame With optional convection ventilator combustion air box Dimensions 32 Falcon 66 56...

Page 33: ...9 9 3 Appliance with 3 sided classic frame Dimensions Falcon 66 56 33...

Page 34: ...9 9 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 66 56...

Page 35: ...they have manifested themselves 3 Complaints will only be accepted if they are reported to the Barbas dealer together with the serial number of the Barbas appliance which is stated on the front of the...

Page 36: ...oes not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warranty cond...

Page 37: ...Warranty Terms Falcon 66 56 3 37...

Page 38: ...Warranty Terms 3 38 Falcon 66 56...

Page 39: ...Warranty Terms Falcon 66 56 3 39...

Page 40: ...Y Your Barbas dealer 001 21 08 2018 347116...

Reviews: