10
Maintenance
Warning:
Make sure that the appliance has cooled down completely before doing the
procedures in this section.
Do all procedures in this section when necessary.
10.1
Appliance
1.
Remove ashes from the floor of the combustion chamber.
2.
Examine the door seals. Replace damaged seals.
3.
Remove the grate and empty the ash tray.
4.
Examine the two baffles for damage. Replace when damaged. Refer to section
for access to the baffles.
5.
Clean both sides of the glass with glass spray or ceramic hob cleaner.
6.
Clean the inside of the appliance with a soft brush.
7.
Clean the metal parts on the outside of the appliance with a dry lint free cloth. Use
Barbas heat resistant paint spray to repair lacquer damage.
10.2
Combustion air supply
1.
Make sure that the inlet of the pipe of the external combustion air supply is not
blocked by leaves or other debris.
2.
Clean the inlet of the pipe of the external combustion air supply.
10.3
Convection air system
Preliminary requirements
• Do the procedure in this section only when a convection air system has been installed.
Procedure
1.
Clean the 2 inlet openings of the convection air in the chimney breast.
2.
Clean the 2 outlet openings of the convection air in the chimney breast.
10.4
Chimney
Note:
It is recommended to contact a registered chimney sweep company to inspect
and clean the chimney.
1.
Remove the heat shield, lower baffle and upper baffle before the chimney sweep
work. Refer to sections
for the procedure to remove the heat shield
and the baffles.
2.
Sweep and inspect the chimney
3.
Make sure there is no blockage in the chimney, for example by birds' nests.
4.
Examine for cracks, loose parts and flue gas leakage. It is recommended to use an
inspection camera.
5.
Install the heat shield, lower baffle and upper baffle. Refer to sections
to
for the procedure to install the heat shield and the baffles.
Maintenance
42
Cuatro-7 75-60
Summary of Contents for Cuatro-7 75-60
Page 6: ...1 Declaration of performance Declaration of performance 6 Cuatro 7 75 60...
Page 56: ...11 2 Connections on Opti Air system Technical data 56 Cuatro 7 75 60...
Page 59: ...12 Dimensions 12 1 Cuatro 7 75 60 with built in frame Dimensions Cuatro 7 75 60 59...
Page 60: ...12 2 Cuatro 7 75 60 with built in frame and convection casing Dimensions 60 Cuatro 7 75 60...
Page 66: ...12 8 Cuatro 7 75 60 with classic frame Dimensions 66 Cuatro 7 75 60...
Page 67: ...12 9 Cuatro 7 75 60 with classic frame and convection casing Dimensions Cuatro 7 75 60 67...
Page 75: ...Warranty Terms Cuatro 7 75 60 75...
Page 76: ...Your Barbas dealer 001 28 06 2022 352574 271 001...