15
Cuatro-3 90
Instructions for use
5
USE
5.1 VENTILATION
If wood is to burn, it needs air. For each kilo of wood that you put on the appliance (door
closed), 10 - 15 m
3
of extra air is needed. That means about 35 m
3
per hour"
Depending on how the appliance has been installed, the combustion air will either be
drawn directly from outside or from the living room itself. If the air is drawn in from the
room, it must be ventilated by an opening in the external wall.
The air drawn in from outside (opening in the external wall) may be " tted with a sliding
grille or # ap. Ensure that the # ap is always open before using the appliance.
5.2 GETTING THE APPLIANCE GOING
When you start the appliance, the chimney is still cold and there is little draught. This
means that the chimneys capacity to draw in air is limited. That is why the air supply
has to be assisted by opening the locking (and/or the door) and air supply slider. Use
dry
, " ne wood and some scrunched-up paper or " relighters to start the appliance.
Locking all the way to the left (closed):
Flue gas # ap operation works normally:
Door open
Pin comes forwards Flue gas # ap open
Door closed Pin is pressed in by the door Flue gas # ap closed
Locking all the way to the right (open):
Flue gas #
ap always remains fully open ""
Locking for operating pin of # ue gas # ap (inside of door).
Locking closed (turned to the left)
Locking open (turned to the right)
close
open
Summary of Contents for CUATRO-3 90
Page 2: ......
Page 4: ...4 Cuatro 3 90 Instructions for use...
Page 31: ......
Page 32: ...02 100613 332875 Your Barbas dealer...
Page 34: ......
Page 36: ...4 CUATRO 3 90 Installation instructions...
Page 38: ...6 CUATRO 3 90 Installation instructions...
Page 58: ...26 CUATRO 3 90 Installation instructions Opening of 4 convection air outlets...
Page 101: ...69 CUATRO 3 90 Installation instructions...
Page 102: ...70 CUATRO 3 90 Installation instructions...
Page 103: ......
Page 104: ...01 150613 332965 Uw Barbas dealer...