 УСТАНОВКА ВАРОЧНОЙ ПОВЕРХНОСТИ 

 

Убедиться в превосходном состоянии и устой-

чивости элемента мебели, в который будет устанав-
ливаться оборудование (Норматив DIN 68930). 

Подготовить проем указанных размеров 

рис. 9a-9b

; если 

варочная поверхность будет установлена сверху печи, 
необходимо предусмотреть разделительную панель, на-
ходящуюся на расстоянии, по меньшей мере, 1 cм от ее 
днища, просверленного в нижней части для прокладки 
газовой трубы и электропитания оборудования (рис.10).

16

[mm]

[mm]

[mm]

[mm]

У

с

тановка / 

Built-in

У

ровневая /

 

F

lush

40

40

65

65

1,2

1

1

[mm]

[mm]

340

490

595

490

850

490

513

618

595

490

R=7,5

513

873

850

490

R=7,5

[mm]

[mm]

90

90

513

363

340

490

R=7,5

9A

 BUILT-IN UNIT INSTALLATION 

 

Make certain that the cabinet in which you will 

be installing the appliance is in perfect condition and 
completely stable (Standard DIN 68930). 

Prepare an embedded hole with measurements as specified in 

figures 9A-9B

; if the appliance is to be installed above an oven, it 

is also necessary to provide an isolating panel with a distance of 
at least 1 cm from the base of the appliance; the isolating panel 
must be placed under the appliance to allow for the gas pipe and 
the appliance’s supply of electrical power.

Summary of Contents for 1PLB0604#-00--1 series

Page 1: ...bs QVWDOODWLRQ DQG XVH PDQXDO 1PLB0604 00 1 PLB0604 00 1 1PLB0904T 00 1 PLB0904T 00 1 1PLB0902T 00 1 PLB0902T 00 1 1PLB1203T 00 1 PLB1203T 00 1 1PLBC0902T 00 2 PLBC0902T 00 2 PLB0604F 00 PLB0904TF 00...

Page 2: ...ral information 2014 35 UE 2014 30 UE 2016 426 Themanufacturerreservestherighttomakeanychanges deemed suitable to the product without prior notice The drawings installation diagrams and tables contain...

Page 3: ...power mains 10 Gas connection 12 Regulating the minimum 14 Gas conversione 15 Built in unit installation 16 USAGE 19 Safety warnings 19 Before starting 21 Understanding the appliance 21 Control panel...

Page 4: ...455 510 895 870 382 68 190 270 68 12 382 68 188 270 68 12 mm 65 65 1PLB0604 00 1 587 80 R 6 R 6 510 615 R 6 mm mm 90 90 120 120 1PLB1203T 00 1 1PLBC0902T 00 2 68 383 68 442 268 12 1150 455 R 6 510 870...

Page 5: ...5 mm mm mm mm 65 65 90 90 120 120 90 90 5 1 0 80 40 80 7 6 5 1 0 1 6 480 400 80 400 80 7 6 5 480 80 80 80 40 80 80 40 80 80 40 80 PLB0604F 00 PLB1203TF 00 PLB1203TF 00 PLB1203TF 00...

Page 6: ...94 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 0 45 kW 0 45 kW 0 50 kW 0 50 kW 0 45 kW 0 45 Rapid 3 kW G30 G31 G30 G31 G20 G25 3 30 mbar 37 mbar 50 mbar 50 mbar 20 mbar 25 mbar g h 218 g h 218...

Page 7: ...nel only as specified in this booklet The connection systems gas and electric and installa tionroomsmustbesuitableandsatisfythesafetystand ards in force in the country of use protective isolating swit...

Page 8: ...s polystyrene etc unattended astheyarea potential hazard for children and animals danger of suffocation Move the appliance to the installation location using appropriate personal safety equipment figu...

Page 9: ...mbustion as specified in the standards in force UNI CIG 7129 and 7131 Openings with an area of at least 100 cm2 must be constructed in such a way so that they cannot be obstructed from neither the ins...

Page 10: ...ion of the two appliances must be independent for electrical safety reasons The power cord must NOT be crushed or rolled up come into contact with any type of liquid sharp or hot objects or corrosive...

Page 11: ...f the appliance is already connected disconnect the electrical power and shut off gas supply taps To access the electrical connections remove the cover from the terminal board by unscrewing the screws...

Page 12: ...ntenance operations Checkthegastypewhichwillpowertheappliance Liquid Gas G30 G31 or Methane G20 25 and ensure that the appliance is compatible with this in the case where it is not compatible adapt it...

Page 13: ...regulating the minimum if necessary consult page 14 When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after...

Page 14: ...towards the left to increase the flame in order to ascertain the desired idle setting If powered by Universal LPG the adjustment screw controlling the idle mode setting must be completely screwed in...

Page 15: ...the identification mark and the nozzle table on page 6 In thecasewhereyoucarryoutanapplianceregulationopera tion for a gas type that differs from the above mentioned appendedtothepresentdocumentation...

Page 16: ...et in which you will be installing the appliance is in perfect condition and completely stable Standard DIN 68930 Prepare an embedded hole with measurements as specified in figures9A 9B iftheappliance...

Page 17: ...17 17 mm mm 90 90 90 90 875 435 458 898 875 435 R 7 5 mm mm 860 490 513 873 860 490 R 7 5 mm mm 120 120 1130 435 458 1153 1130 435 R 7 5 Built in Flush 1 2 1 1 mm mm 9B...

Page 18: ...10A part 2 Seal the gap between the panel and lowering with sili cone figure 10A part 3 and remove any excess figure 10A part 4 EMBEDDED SURFACES Subsequently arrangetheapplianceabovetheembed ded hole...

Page 19: ...vice Centre and re port the data indicated on the data plate Thisapplianceisnotsuitedforusebypersons including children with physical sensorial or mental difficulties or lacking proper experience and...

Page 20: ...verheatuptincansorhermeticallyclosedcontainersontheap pliance theexcesspressuregeneratedbytheheatmaycausecon tainerstoexplode consequentlyleadingtoseriouspersonalinjury Monitor the appliance during th...

Page 21: ...zato solamente in locale ben areato Consultare il libretto istruzioni prima di installare e usare l aparecchio REGOLATO A GAS G20 N XXXXXXXXX CATEGORIA II 2H3 IT F lli BARAZZA s r l MADE IN ITALY Qn g...

Page 22: ...der to determine which knob controls which cook ingzone consultthevelvettouchscreenwhichappears nexttotheknobs whichclearlyanddefinitivelyidentifies which knob regulates which burner figures 13A 13B 6...

Page 23: ...g its com ponents as specified in the Chapter Routine Maintenance on page 28 During this time the appliance may emit smoke or un pleasant odours due to the burning of the grease used in the factory pr...

Page 24: ...king the gas flow from the nozzle subse quently preventing unburned gas from filling the room Switching on the burners 1 figure 14 Press down fully on the knob regulating the burner you wish to switch...

Page 25: ...ialsandsuitableforcontactwithfoods For enhanced burner performance you must use containers withdiametersproportionedtotheburnertypechosen so that you get maximum performance using the minimum amount o...

Page 26: ...ew minutes after use some parts of the appliance reach extremely high temperatures Do not touch these parts without suitable personal protection Switching off the burners 5 Once you have finished cook...

Page 27: ...rts of the appliance using only the procedures and products indicated in this manual in particular do not use abrasive sponges scrapers acidic or aggressive detergents steam or pressure cleaning devic...

Page 28: ...t been accidentally moved from the off position Flame distributors burners racks after the com ponents have cooled down remove them from their housing and wash them with hot water mixed with washing u...

Page 29: ...pter disconnect it from the power and gas supply Ensurethatuponfinishingcleaning thatyouhave correctly replaced the racks taking care not to invert them Theracksmustbestableandmustrestonthehob without...

Page 30: ...than Italy you must comply with the regulations in force in your country Before disposing of the appliance render it unusable by removing the power cord AFTER SALES SERVICE Barazza srl ensures you th...

Page 31: ......

Page 32: ...o grafico Artlinea cod PLAB7 rev05 05 2018 Barazza srl 31025 Sarano di S Lucia di Piave TV ITALIA Via Risorgimento 14 Tel 39 0438 62888 Fax 39 0438 64901 info barazzasrl it www barazzasrl it taste of...