background image

                 

RoadRunners BRR-L Programming guide  

dec 2006 

 

© Baracoda 2006  

28/29 

 
 

Control Characters: 

 

Name 

Programming label 

CR 

 

EOT 

 

ETX 

 

LF 

 

NUL 

 

SOH 

 

STX 

 

TAB 

 

Summary of Contents for BBR-LA

Page 1: ...lity and fi tness for a particular purpose We shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing performance or use of this mater...

Page 2: ...2 8 1 Bluetooth name 11 2 8 2 Sniff settings 12 2 8 3 Power emission settings 12 2 8 4 Security code PIN settings 12 2 9 Prefix and suffix 13 2 9 1 Prefix suffix 13 2 9 2 Postrefix postsuffix 14 3 DEC...

Page 3: ...g labels must be Code128 with specific starting and ending characters These labels will always be read even if Code128 symbology is disabled The scanner will acknowledge a good and valid programming b...

Page 4: ...ility to store barcodes in its internal memory both in batch mode and in Real Time with No Data Loss Mode ON By reading the following barcode you will empty the internal memory of the scanner Empty me...

Page 5: ...to defaults 2 3 3 No data loss mode and Baracoda Header Baracoda header It is a proprietary data encapsulation It is necessary to activate it to use the Baracoda keyboard emulation Kemul and Hyper ter...

Page 6: ...of configuration Noted that the timestamp must fit the specific following format YY MM DD HH MM SS The setting is made by scanning the 0 9 labels Appendix 1 as on a calculator following the timestamp...

Page 7: ...very close each others and they have to be sure to always read the corect one Once in this mode in order to read a barcode user will have to press the trigger twice Pressing it the first time will sw...

Page 8: ...he user will have to read the discharge barcode 2 5 1 Real time mode Important reminder if an ACK beep or bufferisation is needed the scanner must be set in the no data loss mode first See part 1 2 2...

Page 9: ...all the data in its memory If not in batch mode and not connected the BRR L will ignore this barcode For CPU firmware versions 3 16 only the following upload barcode is available Upload batch data Whe...

Page 10: ...have to scan this barcode Enable Dock UART Note When the RS232 cable is not connected it is possible to communicate with the scanner over Bluetooth 2 7 Buzzer and Led Settings You can use these option...

Page 11: ...the scanner Bluetooth name name that you see during a search of Bluetooth peripheral Feature enabled for CPU firmware version 3 00 Set BT Name End of config Read Set BT name label START Read intermed...

Page 12: ...iff period 100ms Sniff period 200ms Sniff period 300ms Sniff period 500ms 2 8 3 Power emission settings You can configure your scanner to work at 20 dBm default setting or 10 dBm Due to local laws you...

Page 13: ...s of more than 32 characters will not be accepted to every barcode sent to the host device There is no prefix suffix in default settings PREFIX on PREFIX off SUFFIX on SUFFIX off max length of the Suf...

Page 14: ...e is no postprefix postsuffix in default settings POST PREFIX on POST PREFIX off POST SUFFIX on POST SUFFIX off max length of the Suffix Prefix is 32 characters Set postprefix Set postsuffix End of co...

Page 15: ...ilable in Appendix2 Symbology identifier AIM not transmitted Symbology identifier AIM transmitted 3 3 Voting Standard voting set is 2 This means that a barcode is considered read by the decoder if the...

Page 16: ...6 Set barcode length END of config 3 6 Codabar settings Codabar not active Codabar active Codabar start stop not transmitted Codabar start stop transmitted Codabar check digit AIM recommendation not u...

Page 17: ...r barcode length Min 6 3 7 Code 11 Settings Code 11 not active Code 11 active Code 11 check digits 1 digit Code 11 check digits 2 digits Code 11 check digits checked and transmitted Code 11 check digi...

Page 18: ...aracters only Trioptic Code 39 Code 39 start stop accepted characters and standard and Trioptic Code 39 Code 39 check digit not used Code 39 check digit modulo 43 checked and transmitted Code 39 check...

Page 19: ...1 included in an EAN128 code is transmitted by default as GS Group Separator 0x1D Feature enablde for CPU firmware version 3 00 Enable GS transmission Disable GS transmission It is possible to replace...

Page 20: ...00 Enable AIM ID transmission for EAN128 Disable AIM ID transmission for EAN128 3 11 Interleaved 2 of 5 Settings Interleaved 2 of 5 not active Interleaved 2 of 5 active Interleaved 2 of 5 check digit...

Page 21: ...arcode length minimum length 6 3 13 Standard 2 of 5 Settings Standard 2 of 5 not active Standard 2 of 5 active Standard 2 of 5 check digit mod 10 not used Standard 2 of 5 check digit mod 10 checked an...

Page 22: ...ber system UPC A transmitted UPC EAN UPC number system UPC A not transmitted V T V T F N C 4 N U L E O T D D S O H Q F F F F Di sabl e UPCA Num ber Syst em t r ansm i ssi on UPC EAN UPC number system...

Page 23: ...arcodes Read Start Set min Max length label START Read intermediary label Corresponding to the next digit of the min Max length value to apply as on a calculator Finished Read END of config label END...

Page 24: ...a 2006 24 29 Symbology table Header Selected Symbology SELECT ALL Code 93 Code 128 EAN 128 EAN 13 UPC A Code 39 Codabar Interleaved 2 of 5 Standard 2 of 5 industrial 2 of 5 Code 11 MSI UPC E EAN 8 Sta...

Page 25: ...mming guide dec 2006 Baracoda 2006 25 29 APPENDIX 1 ASCII Table A Z a z 0 9 ponctuation Control characters Capital letters A Z Name Programming label Name Programming label A N B O C P D Q E R F S G T...

Page 26: ...RoadRunners BRR L Programming guide dec 2006 Baracoda 2006 26 29 Small letters a z Name Programming label Name Programming label a n b o c p d q e r f s g t h u i v j w k x l Y m z Ponctuation Space...

Page 27: ...RoadRunners BRR L Programming guide dec 2006 Baracoda 2006 27 29 L F L F L F L F _ Decimal numbers 0 9 Name Programming label 0 1 2 3 4 5 6 7 8 9...

Page 28: ...RoadRunners BRR L Programming guide dec 2006 Baracoda 2006 28 29 Control Characters Name Programming label CR EOT ETX LF NUL SOH STX TAB...

Page 29: ...r character is determined by summing the option values of each symbology If the sum is greater than 9 use A B C D E F in the place of 10 11 12 13 14 and 15 Code 39 Option Values 0 No check character o...