8 Maintenance of the unit
8.1 Cleaning
When cleaning the kaloMAX, take care that no liquid is spilled into the inside of the unit. The
upper side is not completely sealed.
8.2 Replacement of the driving belt
If the driving belt has to be changed because of insufficient traction, this can be done without
opening the unit:
•
Remove the cover of the left bearing.
•
Remove the driving belt.
•
Pass the new driving belt through the slot in the cover plate
and put it around the lower drive wheel (B).
•
Put the driving belt around the drive wheel of the shaft(A).
The belt is guided over the inner side of the tension pulley (C).
•
Attach the cover to the left bearing.
8.3 Fuses
Two 1 A delay-action fuses are placed in the power supply unit (double pole fuse protection).
8.4 Replacement of the driveshaft
If the traction rings on the driveshaft are damaged, it is best to replace the whole shaft,
because the tractions rings can only be trimmed for exact running when mounted on the shaft.
The cover of the left bearing has to be removed. After releasing the screws on both sides of
the driveshaft, the whole unit including the bearings can be pulled out to the left.
8.5 Replacement parts
Order No.
Driving belt
O-Ring 85 x 3
50-113
Driveshaft
complete with trimmed traction rings, in exchange
50-112
Fuses
T 1 A