BC6
Display
Display
The value of discharge current on the left side of screen
may not exceed 1C for a maximum safety and the final
voltage on the right should not be under the voltage
level that is recommended by the battery manufacturer
to avoid deep discharging.
To start to discharge press key for more than 3
seconds.
This shows the present state of discharge. To stop
discharging press key once.
Discharging Lithium battery
LiPo DISCHARGE
1.0A 11.1V(3S)
Li3S 0.4A 12.59V
DSC 022:43 00682
+
-
+
-
'>3 seconds'
Batt type
Stop
DEC
◀
INC
▶
Start/
Enter
DEC
◀
INC
▶
battery
voltage
discharge
current
discharged
capacity
elapsed
time
number
of
cells
Start
Enter
Batt type
Stop
* Voltage balancing and monitoring during the discharge
The processor monitors the voltage of individual cells during 'storage-mode' and 'discharge'
of Lithium battery pack. It tries to normalise the voltages to be equal. For this feature, the
individual plug of the battery pack should be connected to the individual port of the charger.
If the voltage of any one or more cells varies abnormally during the procedure, BC6
terminates the process forcibly with the error message. If this happens, the battery pack
contains the bad cell, or the bad connection of the cable or plug. You can easily know which
one cell is bad by pressing button at time of showing the error message.
Display
Display
INC
▶
BATTERY VOL ERR
CELL LOW VOL
The processor found that the voltage of one of the
cell in the Lithium battery pack is too low.
In this case, the 4th cell is bad. If there happens
the connection-break of the cable or plug, the
voltage value may show zero.
I N C
▶
- 12 -
4 . 1 4 4 . 1 6 4 . 0 9
2 . 1 8 0 . 0 0 0 . 0 0