SELF-CONTAINED MODELS
2x
1x
Unlock push buttons (flashing Green and Amber 1X followed by acceptance flash) default
Lock push buttons (flashing Green and Amber 2X followed by acceptance flash)
4x
3x
Enable Auto compensation (flashing Green and Amber 3X followed by acceptance flash)
Disable Auto compensation (flashing Green and Amber 4X followed by acceptance flash)
default
5x
Enable 30 ms Off Delay (flashing Green and Amber 5X followed by acceptance flash)
6x
Disable 30 ms Off Delay (flashing Green and Amber 6X followed by acceptance flash) default
1x
2x
Basic Configuration (alternating flashing Green and Amber LEDs at 1Hz)
Advanced Configuration (simultaneous flashing both Green and Amber LEDs at 1Hz)
Starts Selected Teach
(same function as pressing Teach Button for > 2 sec)
40 ms < T < 800 ms
Timing between Pulse groups > 800 ms
Rempte Input Wire Pulse Timing (T)
(White wire is remote input wire)
3x
Toggle TEACH Button Lock/Unlock (flashing both Green and Amber LEDs 4X followed by acceptance flash)
4x
Reset to Factory Defaults
** Remote Input Wire only. Using Push Button will not reset sensor to factory defaults.
(flashing both Green and Amber LEDs 8X followed by acceptance flash)
8x
Push Button or
Remote Input Wire*
*Configuration using remote input wire
when enabled through IO-Link
1x
Second Pulse Completes Teach (2-Point Static and Dynamic Teach only)
Configure output to Light Operate (flashing Green and Amber 1X followed by acceptance flash)
Configure output to Dark Operate (flashing Green and Amber 2X followed by acceptance flash) default for LP models
default for D, DV, CV and FP models
Configure offset percentage to 10% (flashing Green and Amber 3X followed by acceptance flash)
Configure offset percentage to 30% (flashing Green and Amber 4X followed by acceptance flash)
Configure offset percentage to 50% (flashing Green and Amber 5X followed by acceptance flash)
Select 2-Point Static TEACH default for D, DV, CV, and FP models
Select Dynamic TEACH
Select Window SET
Select TEACH/SET Method (flashing Amber LED at 1Hz)
Select Light SET
Select Dark SET
2x
1x
4x
3x
5x
5x
2x
1x
4x
3x
5x
Note: Reconfiguration is required before a new TEACH/SET method takes effect.
default
default for LP models
Hold is > 2 sec. and < 4 sec.
Click is > 40 ms and < 800 ms